AD-147 - Switch Nexa - Free user manual and instructions
Find the device manual for free AD-147 Nexa in PDF.
| Product Type | Wireless Switch |
| Brand | Nexa |
| Model | AD-147 |
| Dimensions (H x W x D) | 80 x 80 x 20 mm |
| Weight | 50 g |
| Power Supply | 1 x CR2032 battery (included) |
| Operating Frequency | 433 MHz |
| Range | Up to 30 m (open space) |
| Functions | On/Off control of compatible Nexa receivers |
| Mounting | Wall-mounted or handheld |
| Color | White |
| Material | ABS plastic |
| Battery Life | Approximately 1 year under normal use |
| IP Rating | IP20 (indoor use only) |
| Operating Temperature | 0°C to 40°C |
| Maintenance | Clean with a soft, dry cloth. Do not use water or solvents. |
| Safety Precautions | Keep away from water and moisture. Do not disassemble. Replace battery promptly when low. |
| Spare Parts | Battery (CR2032), screw covers |
| Repairability | Not user-serviceable apart from battery replacement |
| Certifications | CE, RoHS |
Frequently Asked Questions - AD-147 Nexa
User questions about AD-147 Nexa
0 question about this device. Answer the ones you know or ask your own.
Ask a new question about this device
Download the instructions for your Switch in PDF format for free! Find your manual AD-147 - Nexa and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AD-147 by Nexa.
USER MANUAL AD-147 Nexa
AD-147 Plug-in mottagare Dimmer/ Plug-in receiver Dimmer
Link Key (On/Off)


Svenska
AD-147 is a small Z-Wave plug-in dimmer receiver that easily is connected between wall socket and load. It can be controlled by Nexa Bridge or other Z-Wave controller. AD-147 has a button for control without a remote.
Safety
Read the instructions first.
Call in professional as needed. Nexa can not be held responsible if it is used for other purposes than it is designed for, or if instructions are not followed. Never connect the lights or equipment that exceeds the recipient's maximum load. It can lead to failure, short circuit or fire. Do not attempt to repair the product. It contains no serviceable parts. The product is not waterproof. Make sure it is completely dry. Do not use chemicals, solvents or harsh detergents. Do not expose to extreme heat or cold.
Technical information
Power supply 230 V \~50 Hz
Load 6-250 W resistive load
Frequency Z-Wave (868,42 MHz)
Range
Dimensions
Environment temp. range
Up to 30 m
Ø52 x 78 mm
-10°C-35°C
Installation
Put the plug-in receiver in the wall socket. Put the loads plug in the receiver.
AD-147 is able to remember the status of the relay when power is cut off (such as power black-out). When power is supplied again, the unit will resume the last status of the relay (on or off) automatically. This can be changed in the Z-Wave controller.
Adding to a Z-Wave network
The button marked [Link Key] on the unit is used to include, exclude and reset the unit.
See Z-Wave controller manual how inclusion/exclusion is done.
The Led flashes 0.5 Hz when no Node ID is stored.
Auto inclusion
If the unit has no Node ID and is powered it enters auto inclusion mode for 4 minutes.
| Include | Press [Link Key] 3 times within 1,5 seconds. |
| Exclude | Press [Link Key] 3 times within 1,5 seconds. |
| Reset | Press [Link Key] 3 times within 1,5 seconds. Then, within 1 seconds, press and hold [Link Key] until LED turns off.The unit is now reset and enters auto inclusion mode. |
For more information regarding how to program the Z-wave unit, see the other side.
Operation
Operation with Z-Wave controller
See Z-Wave controller's manual
Operation with the button [Link key]
Push once to turn on light, push once again to turn off. Push and hold when light is on to dim. When the light is turned back on, it will have the same light intensity as it had when turned off.
more information at:
www.nexa.se/zwave
Programming
Z-Wave Group Support
The unit supports two association groups with 1 node support for Grouping 1 and 4 nodes support for Grouping 2. This has the effect that when the unit is operating, all devices associated with the unit will receive the relevant reports.
- When the unit is powered up and is already a part of a Z-Wave network, the unit will send a Notification Report to the node in Group 1.
- When setting the unit or changing the unit's status, the unit will send a Multilevel Switch Report to the node of Group 1.
- When performing Reset the unit will send Device Reset Locally Notification to the node of Group1.
- The minimum interval time between two reports sent from this unit to the node of Group 1 is 3 seconds. Refer to Configuration parameter 2 for more information
- When the button on the unit or the wall switch (S1) is pressed, the unit will send a Basic Set command to the nodes of Group 2. When the unit is OFF, Basic Set Value = 0x00. When the unit is ON, Basic Set Value = 0xFF.
Z-Wave Plus Info
| Role Type Node Type Installer Icon User Icon | |
| Slave Always On Z-Wave Plus node Light Dimmer Switch Light Dimmer Switch | |
Version
| Protocol Library 3 (Slave_Enhance_232_Library) | |
| Protocol Version 3.95 (6.51.02) | |
Manufacturer
| Manufacturer ID Product Type | Product ID | |
| 0x0060 0x0003 0x0003 |
AGI (Association Group Information) Table
| Group Profile Command | Class & Command (List)N bytes | Group Name(UTF-8) | |
| 1 General:NA | Multilevel Switch Report,Notification Report,Device Reset Locally Notification | Lifeine | |
| 2 | Control:Key1 | Basic Set | On/Off control(Button1) |
Basic
- Basic Get: Inquire about the status of the device.
● Basic Report: Report the status of the device. - Basic Set: Set the status of the device.
| Basic Set Value | Description |
| 0x00 | Device OFF |
| 0x01 - 0x63 Device ON | output Level as the specified Value. |
| 0xFF | Device ON, output Level as the last memorized Level. |
Notification
The device will send notifications (Notification Type =0x08, Event = 0x01) upon being
Configuration
The configurable values are as following:
Basic Set Command value:
| Parameter Number Size | Range | Default | |
| 1 | 2 | 0~99_255(0xFF) | 255 (0xFF) |
The delaying time to report to Group 1
| Parameter Number Size | Range | Default | |
| 2 | 1 | 3 - 25 (seconds) | 3 |
Remember the last status:
| Parameter Number Size | Range | Default |
| 3 | 1/0 | 1: remember(0: do not remember) |
Output mode setting: Dimming, On/Off
| Parameter Number Size | Range | Default |
| 5 | 1/0 | 1: Dimming(0: On/Off) |
Note: When set to 1, the operation mode is not changed; only the light would be turned on with 100% brightness immediately.
Command Classes
The module supports Command Classes including.
● COMMAND_CLASS_ZWAVEPLUS_INFO_V2
• COMMAND_CLASS_VERSION_V2
● COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
- COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
- COMMAND_CLASS_ASSOCIATION_V2
● COMMAND CLASS ASSOCIATION GRP INFO V1
● COMMAND CLASS POWERLEVEL V1
● COMMAND CLASS BASIC V1
COMMAND_CLASS_NOTIFICATION)
COMMAND_CLASS_NOTIFICATION_V4
COMMAND_CLASS_CONFIGURATION
- COMMAND_CLASS_CONFIGURATION_VT
• COMMAND_CLASS_SWITCH_MULTILEVED
- COMMAND_CLASS_SWITCH_ALL_V1
• COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
Additional Command Classes Supported
● Power Level: For test purpose during product installation.
● Multilevel Switch: Refer to Basic
- Switch All: The device turns on when receiving "Switch All On", and turns off upon
receiving "Switch ALOff"
● Firmware Update: For OTA function
,
CE DECLARATION OF CONFORMITY
Is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Radio Equipment and Telecommunications Terminal Equipment (RED) Directive 2014/54/EU, Low-voltage Directive (2014/35/EU). For the evaluation regarding the Directives, the following standards were applied:
EN301489-1 V1.9.2
EN301489-3 V1 6 1
EN301189 5 V1.6.1 EN300220 1 V2.4.1
EN366220-1-V2.4.1
EN300220-2 V2.4.1
EN61058-1: 2002/A2: 2008
DIN VDE 0620-2-1·2013
Company Name:
| Adress: | Karl-Johansgatan 152, 40242, Göteborg, Sweden |
| Signatur: |
Name: Erik Hielmströ
Title: Miss Dependent
Date: Place: 17 May 2016. Göteborg
Date, 1 April