Nexa AD-147 - Switch

AD-147 - Switch Nexa - Free user manual and instructions

Find the device manual for free AD-147 Nexa in PDF.

📄 2 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Nexa AD-147 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Wireless Switch
Brand Nexa
Model AD-147
Dimensions (H x W x D) 80 x 80 x 20 mm
Weight 50 g
Power Supply 1 x CR2032 battery (included)
Operating Frequency 433 MHz
Range Up to 30 m (open space)
Functions On/Off control of compatible Nexa receivers
Mounting Wall-mounted or handheld
Color White
Material ABS plastic
Battery Life Approximately 1 year under normal use
IP Rating IP20 (indoor use only)
Operating Temperature 0°C to 40°C
Maintenance Clean with a soft, dry cloth. Do not use water or solvents.
Safety Precautions Keep away from water and moisture. Do not disassemble. Replace battery promptly when low.
Spare Parts Battery (CR2032), screw covers
Repairability Not user-serviceable apart from battery replacement
Certifications CE, RoHS

Frequently Asked Questions - AD-147 Nexa

How do I pair the AD-147 switch with a Nexa receiver?
Press and hold the pairing button on the receiver until the LED blinks, then press the button on the AD-147 once. The LED will stop blinking to confirm pairing.
What is the maximum operating range?
The range is up to 30 meters in open space. Walls and obstacles may reduce the range.
What type of battery does the AD-147 use?
It uses a CR2032 lithium coin cell battery, which is included.
How long does the battery last?
Under normal usage, the battery lasts approximately 1 year. Replace when the range decreases or the LED is dim.
Can I mount the switch on the wall?
Yes, the AD-147 can be mounted on the wall using the included screws and wall plugs, or used as a handheld remote.
Is the AD-147 compatible with other Nexa products?
It is designed to work with most Nexa receivers such as the MR-230, AR-300, and similar 433 MHz devices.
What should I do if the switch stops working?
First, replace the battery. If that does not help, try re-pairing the switch with the receiver. If the issue persists, contact Nexa support.
Can I use the AD-147 outdoors?
No, the switch is rated IP20 and is intended for indoor use only. Exposure to moisture may damage it.
How many receivers can I control with one switch?
One AD-147 can control multiple receivers if they are all paired to the same switch. However, it sends a single on/off command to all.
Is there a way to reset the switch to factory settings?
To reset, remove the battery, wait 10 seconds, and reinsert it. This clears all paired receivers.

User questions about AD-147 Nexa

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Switch in PDF format for free! Find your manual AD-147 - Nexa and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. AD-147 by Nexa.

USER MANUAL AD-147 Nexa

AD-147 Plug-in mottagare Dimmer/ Plug-in receiver Dimmer

Link Key (On/Off)

Technical line drawing of a cylindrical mechanical component with internal slots and a labeled 'Lin' arrow (no text or symbols beyond label)

Nexa AD-147 - AD-147 Plug-in mottagare Dimmer/ Plug-in receiver Dimmer - 2

Svenska

AD-147 is a small Z-Wave plug-in dimmer receiver that easily is connected between wall socket and load. It can be controlled by Nexa Bridge or other Z-Wave controller. AD-147 has a button for control without a remote.

Safety

Read the instructions first.

Call in professional as needed. Nexa can not be held responsible if it is used for other purposes than it is designed for, or if instructions are not followed. Never connect the lights or equipment that exceeds the recipient's maximum load. It can lead to failure, short circuit or fire. Do not attempt to repair the product. It contains no serviceable parts. The product is not waterproof. Make sure it is completely dry. Do not use chemicals, solvents or harsh detergents. Do not expose to extreme heat or cold.

Technical information

Power supply 230 V \~50 Hz

Load 6-250 W resistive load

Frequency Z-Wave (868,42 MHz)

Range

Dimensions

Environment temp. range

Up to 30 m

Ø52 x 78 mm

-10°C-35°C

Installation

Put the plug-in receiver in the wall socket. Put the loads plug in the receiver.

AD-147 is able to remember the status of the relay when power is cut off (such as power black-out). When power is supplied again, the unit will resume the last status of the relay (on or off) automatically. This can be changed in the Z-Wave controller.

Adding to a Z-Wave network

The button marked [Link Key] on the unit is used to include, exclude and reset the unit.

See Z-Wave controller manual how inclusion/exclusion is done.

The Led flashes 0.5 Hz when no Node ID is stored.

Auto inclusion

If the unit has no Node ID and is powered it enters auto inclusion mode for 4 minutes.

IncludePress [Link Key] 3 times within 1,5 seconds.
ExcludePress [Link Key] 3 times within 1,5 seconds.
ResetPress [Link Key] 3 times within 1,5 seconds. Then, within 1 seconds, press and hold [Link Key] until LED turns off.The unit is now reset and enters auto inclusion mode.

For more information regarding how to program the Z-wave unit, see the other side.

Operation

Operation with Z-Wave controller

See Z-Wave controller's manual

Operation with the button [Link key]

Push once to turn on light, push once again to turn off. Push and hold when light is on to dim. When the light is turned back on, it will have the same light intensity as it had when turned off.

more information at:

www.nexa.se/zwave

Programming

Z-Wave Group Support

The unit supports two association groups with 1 node support for Grouping 1 and 4 nodes support for Grouping 2. This has the effect that when the unit is operating, all devices associated with the unit will receive the relevant reports.

  • When the unit is powered up and is already a part of a Z-Wave network, the unit will send a Notification Report to the node in Group 1.
  • When setting the unit or changing the unit's status, the unit will send a Multilevel Switch Report to the node of Group 1.
  • When performing Reset the unit will send Device Reset Locally Notification to the node of Group1.
  • The minimum interval time between two reports sent from this unit to the node of Group 1 is 3 seconds. Refer to Configuration parameter 2 for more information
  • When the button on the unit or the wall switch (S1) is pressed, the unit will send a Basic Set command to the nodes of Group 2. When the unit is OFF, Basic Set Value = 0x00. When the unit is ON, Basic Set Value = 0xFF.

Z-Wave Plus Info

Role Type Node Type Installer Icon User Icon
Slave Always On Z-Wave Plus node Light Dimmer Switch Light Dimmer Switch

Version

Protocol Library 3 (Slave_Enhance_232_Library)
Protocol Version 3.95 (6.51.02)

Manufacturer

Manufacturer ID Product TypeProduct ID
0x0060 0x0003 0x0003

AGI (Association Group Information) Table

Group Profile CommandClass & Command (List)N bytesGroup Name(UTF-8)
1 General:NAMultilevel Switch Report,Notification Report,Device Reset Locally NotificationLifeine
2Control:Key1Basic SetOn/Off control(Button1)

Basic

  • Basic Get: Inquire about the status of the device.
    ● Basic Report: Report the status of the device.
  • Basic Set: Set the status of the device.
Basic Set ValueDescription
0x00Device OFF
0x01 - 0x63 Device ONoutput Level as the specified Value.
0xFFDevice ON, output Level as the last memorized Level.

Notification

The device will send notifications (Notification Type =0x08, Event = 0x01) upon being

Configuration

The configurable values are as following:

Basic Set Command value:

Parameter Number SizeRangeDefault
120~99_255(0xFF)255 (0xFF)

The delaying time to report to Group 1

Parameter Number SizeRangeDefault
213 - 25 (seconds)3

Remember the last status:

Parameter Number SizeRangeDefault
31/01: remember(0: do not remember)

Output mode setting: Dimming, On/Off

Parameter Number SizeRangeDefault
51/01: Dimming(0: On/Off)

Note: When set to 1, the operation mode is not changed; only the light would be turned on with 100% brightness immediately.

Command Classes

The module supports Command Classes including.
● COMMAND_CLASS_ZWAVEPLUS_INFO_V2
• COMMAND_CLASS_VERSION_V2
● COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
- COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
- COMMAND_CLASS_ASSOCIATION_V2
● COMMAND CLASS ASSOCIATION GRP INFO V1
● COMMAND CLASS POWERLEVEL V1
● COMMAND CLASS BASIC V1
COMMAND_CLASS_NOTIFICATION)
COMMAND_CLASS_NOTIFICATION_V4 COMMAND_CLASS_CONFIGURATION
- COMMAND_CLASS_CONFIGURATION_VT
• COMMAND_CLASS_SWITCH_MULTILEVED
- COMMAND_CLASS_SWITCH_ALL_V1
• COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2

Additional Command Classes Supported

● Power Level: For test purpose during product installation.
● Multilevel Switch: Refer to Basic
- Switch All: The device turns on when receiving "Switch All On", and turns off upon
receiving "Switch ALOff"
● Firmware Update: For OTA function

,

CE DECLARATION OF CONFORMITY

Is herewith confirmed to comply with the requirements set out in the Council Directive on the Approximation of the Laws of the Member States relating to Radio Equipment and Telecommunications Terminal Equipment (RED) Directive 2014/54/EU, Low-voltage Directive (2014/35/EU). For the evaluation regarding the Directives, the following standards were applied:

EN301489-1 V1.9.2
EN301489-3 V1 6 1
EN301189 5 V1.6.1 EN300220 1 V2.4.1
EN366220-1-V2.4.1
EN300220-2 V2.4.1
EN61058-1: 2002/A2: 2008
DIN VDE 0620-2-1·2013

Company Name:

Adress:Karl-Johansgatan 152, 40242, Göteborg, Sweden
Signatur:

Name: Erik Hielmströ
Title: Miss Dependent
Date: Place: 17 May 2016. Göteborg

Date, 1 April

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : Nexa

Model : AD-147

Category : Switch