DBX PS6 - Power Supply

PS6 - Power Supply DBX - Free user manual and instructions

Find the device manual for free PS6 DBX in PDF.

📄 2 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice DBX PS6 - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Power Sequencer
Number of Outlets 6
Input Voltage 120V AC, 60Hz
Maximum Current 15A
Dimensions 19 x 1.75 x 6.5 inches (rack mount 1U)
Weight 5.5 lbs
Power Cord Length 6 feet
Sequencing Delay 1 second between outlets
Surge Protection 1400 Joules
EMI/RFI Filtering Yes
Indicators Status LEDs per outlet
Mounting Rack mountable (1U)
Safety Features Overload and short circuit protection
Material Steel chassis
Operating Temperature 32°F to 104°F (0°C to 40°C)
Warranty 1 year limited
Certifications UL, CE, RoHS
Maintenance Clean with dry cloth; no internal serviceable parts
Spare Parts Not available; unit must be replaced if damaged

Frequently Asked Questions - PS6 DBX

How does the sequential power up function work?
The PS6 powers on outlets one by one with a 1-second delay between each to prevent inrush current and avoid tripping breakers. Power down is simultaneous.
Can I use the PS6 with 220V power?
No, the PS6 is designed for 120V AC only. Using with higher voltage may damage the unit and void warranty.
How many devices can I connect?
Up to 6 devices with a total current draw not exceeding 15A (1800W at 120V).
Does the PS6 protect against power surges?
Yes, it provides 1400 Joule surge protection to safeguard connected equipment from voltage spikes.
Can I mount the PS6 in a rack?
Yes, it is 1U rack mountable and includes rack ears for standard 19-inch racks.
What do the LEDs indicate?
Each outlet has an LED that lights up green when power is applied. A flashing LED may indicate a fault.
Is the PS6 suitable for audio equipment?
Yes, it features EMI/RFI filtering to reduce noise and ensure clean power for sensitive audio gear.
What should I do if a outlet stops working?
First check if the overload protection has tripped. Reduce load and reset by power cycling. If issue persists, contact support.
Can I replace the power cord?
The power cord is hardwired and not user-replaceable. If damaged, the unit should be serviced by a professional.
How do I clean and maintain the PS6?
Disconnect power and wipe with a soft dry cloth. Do not use liquids or solvents. No internal maintenance required.

User questions about PS6 DBX

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Power Supply in PDF format for free! Find your manual PS6 - DBX and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. PS6 by DBX.

USER MANUAL PS6 DBX

Owner's Manual

10653 S. River Front Parkway, Suite 300

South Jordan, UT 84095

PH (801) 566-8800

FAX (801) 566-7005

http://www.dbxpro.com

dbx® is a registered trademark of Harman

Copyright - Harman

PS6 Owner's Manual 5067154-A Printed in USA

SAFETY INSTRUCTIONS

Notice For Customers If Your Unit Is Equipped With A Power Cord.

WARNING: THIS APPLIANCE SHALL BE CONNECTED TO A MAINS SOCKET OUTLET WITH A PROTECTIVE EARTHING CONNECTION.

The cores in the mains lead are coloured in accordance with the following code:

GREEN and YELLOW - Earth BLUE - Neutral BROWN - Live

As colours of the cores in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug, proceed as follows:

The core which is coloured green and yellow must be connected to the terminal in the plug marked with the letter E, or with the earth symbol, or coloured green, or green and yellow.

The core which is coloured blue must be connected to the terminal marked N or coloured black. The core which is coloured brown must be connected to the terminal marked L or coloured red.

This equipment may require the use of a different line cord, attachment plug, or both, depending on the available power source at installation. If the attachment plug needs to be changed, refer servicing to qualified service personnel who should refer to the table below. The green/yellow wire shall be connected directly to the units chassis.

CONDUCTORWIRE COLOR
Normal Alt
L LIVE BROWN BLACK
N NEUTRAL BLUEWHITE
EEARTH GNDGREEN/YELGREEN

WARNING: If the ground is defeated, certain fault conditions in the unit or in the system to which it is connected can result in full line voltage between chassis and earth ground. Severe injury or death can then result if the chassis and earth ground are touched simultaneously.

U.K. MAINS PLUG WARNING

A molded mains plug that has been cut off from the cord is unsafe. Discard the mains plug at a suitable disposal facility.

NEVER UNDER ANY CIRCUMSTANCES SHOULD YOU INSERT A DAMAGED OR CUT MAINS PLUG INTO A 13 AMP POWER SOCKET.

Do not use the mains plug without the fuse cover in place. Replacement fuse covers can be obtained from your local retailer. Replacement fuses are 13 amps and MUST be ASTA approved to BS1362.

ELECTROMAGNETIC COMPATIBILITY

This device complies with part 15 of the FCC Rules and the Product Specifications noted on the Declaration of Conformity. Operation is subject to the following two conditions:

- this device may not cause harmful interference, and

- this device must accept any interference received, including interference that may cause undesired operation.

Operation of this unit within significant electromagnetic fields should be avoided.

- use only shielded interconnecting cables.

WARNING FOR YOUR PROTECTION READ THE FOLLOWING:

KEEP THESE INSTRUCTIONS

HEED ALL WARNINGS

FOLLOW ALL INSTRUCTIONS

THE APPARATUS SHALL NOT BE EXPOSED TO DRIPPING OR SPLASHING LIQUID AND NO OBJECT FILLED WITH LIQUID, SUCH AS VASES, SHALL BE PLACED ON THE APPARATUS.

CLEAN ONLY WITH A DRY CLOTH.

DO NOT BLOCK ANY OF THE VENTILATION OPENINGS.

INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS

DO NOT INSTALL NEAR ANY HEAT SOURCES SUCH AS RADIATORS, HEAT REGISTERS, STOVES, OR OTHER APPARATUS (INCLUDING AMPLIFIERS) THAT PRODUCE HEAT.

ONLY USE ATTACHMENTS/ACCESSORIES SPECIFIED BY THE MANUFACTURER.

UNPLUG THIS APPARATUS DURING LIGHTNING STORMS OR

WHEN UNUSED FOR LONG PERIODS OF TIME.

Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or third prong are provided for your safety. If the provided plug does not fit your outlet, consult an electrician for replacement of the obsolete outlet.

Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

DBX PS6 - WARNING FOR YOUR PROTECTION READ THE FOLLOWING: - 1

Use only with the cart stand, tripod bracket, or table specified by the manufacture, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

POWER ON/OFF SWITCH: If the equipment has a power switch, the power switch used in this piece of equipment DOES NOT break the connection from the mains.

MAINS DISCONNECT: The plug shall remain readily operable. For rack-mount or installation where plug is not accessible, an all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated into the electrical installation of the rock or building.

FOR UNITS EQUIPPED WITH EXTERNALLY ACCESSIBLE FUSE RECEPTACLE: Replace fuse with same type and rating only.

MULTIPLE-INPUT VOLTAGE: This equipment may require the use of a different line cord, attachment plug, or both, depending on the available power source at installation. Connect this equipment only to the power source indicated on the equipment rear panel. To reduce the risk of fire or electric shock, refer servicing to qualified service personnel or equivalent.

If connected to 240V supply, a suitable CSA/UL certified power cord shall be used for this supply.

CAUTION: For Use with Harman Audio/Video Equipment.

WARNING:

The following is indicative of low altitude use; do not use this product above 2000m.

These symbols are internationally accepted symbols that warn of potential hazards with electrical products. The lightning flash means that there are dangerous voltages present within the unit. The exclamation point indicates that it is necessary for the user to refer to the owner's manual.

These symbols warn that there are no user serviceable parts inside the unit. Do not open the unit. Do not attempt to service the unit yourself. Refer all servicing to qualified personnel. Opening the chassis for any reason will void the manufacturer's warranty. Do no get the unit wet. If liquid is spilled on the unit, shut it off immediately and take it to a dealer for service.

Disconnect the unit during storms to prevent damage.

DBX PS6 - WARNING FOR YOUR PROTECTION READ THE FOLLOWING: - 2

If you want to dispose this product, do not mix it with general household waste. There is a separate collection system for used electronic products in accordance with legislation that requires proper treatment, recovery and recycling.

Private household in the 25 member states of the EU, in Switzerland and Norway may return their used electronic products free of charge to designated collection facilities or to a retailer (if you purchase a similar new one).

For Countries not mentioned above, please contact your local authorities for a correct method of disposal. By doing so you will ensure that your disposed product undergoes the necessary treatment, recovery and recycling and thus prevent potential negative effects on the environment and human health.

DECLARATION OF CONFORMITY

Manufacturer's Name: dbx Professional Products

Manufacturer's Address: 8760 S. Sandy Parkway

Sandy, Utah 84070, USA gres that the product:

Product name: dbx PS-6

Note: Product name may be suffixed by the EU.

Product option: None

conforms to the following Product Specifications:

Safety: IEC 60065-01+Amd 1

EMC: EN 55022:2006

EN 55024:

FCC Full TS

Supplementary Information:

The product herewith complies with the requirements of the

Low Voltage Directive 2006/95/EC

EMC Directive 2004/108/EC

KoHS Directive 2002/95/EC

WEEE Directive 2002/76/EC

With regard to Directive 2005/32/EC and EC Regulation 1275/2008 of 17 December 2008, this product is designed, produced, and classified as Professional Audio Equipment and thus is exempt from this Directive.

Rex C. Reed

Director, Engineering

Signal Processing

6700 3. Sunday Parkway Sandy, Utah 84070, USA

Date: April 5, 2013

European Contact: Your local dbx Sales and Service Office or

Harman Professional Inc

8760 South Sandy Parkway

Sandy, Utah

84070 USA

Ph: (601) 566-6800

Fax. (001) 366-7583

SUPPORT / SERVICE

If you require technical support, contact dbx Technical Support. Be prepared to accurately describe the problem. Know the serial number of your device—this is printed on a sticker attached to the chassis. If you have not already taken the time to fill out your warranty registration card and send it in, please do so now. You may also register online at www.dbxpro.com.

Before you return a product to the factory for service, we recommend you refer to the manual. Make sure you have correctly followed installation steps and operation procedures. For further technical assistance or service, please contact our Technical Support Department at (801) 568-7660 or visit www.dbxpro.com. If you need to return a product to the factory for service, YOU MUST FIRST CONTACT TECHNICAL SUPPORT TO OBTAIN A RETURN AUTHORIZATION NUMBER.

NO RETURNED PRODUCTS WILL BE ACCEPTED AT THE FACTORY WITHOUT A RETURN AUTHORIZATION NUMBER.

Please refer to the Warranty information on the following page, which extends to the first end-user. After expiration of the warranty, a reasonable charge will be made for parts, labor, and packing if you choose to use the factory service facility. In all cases, you are responsible for transportation charges to the factory. dbx will pay return shipping if the unit is still under warranty.

Use the original packing material if it is available. Mark the package with the name of the shipper and with these words in red: DELICATE INSTRUMENT, FRAGILE! Insure the package properly. Ship prepaid, NOT COLLECT. DO NOT SHIP PARCEL POST.

WARRANTY

  1. The warranty registration card that accompanies this product must be mailed within 30 days after purchase date to validate this warranty. You can also register online at www.dbxpro.com. Proof-of-purchase is considered to be the responsibility of the consumer. A copy of the original purchase receipt must be provided for any warranty service.
  2. dbx warrants this product, when purchased new from an authorized U.S. dbx dealer and used solely within the U.S., to be free from defects in materials and workmanship under normal use and service. This warranty is valid to the original purchaser only and is non-transferable.
  3. dbx liability under this warranty is limited to repairing or, at our discretion, replacing defective materials that show evidence of defect, provided the product is returned to dbx WITH RETURN AUTHORIZATION from the factory, where all parts and labor will be covered up to a period of two years. A Return Authorization number must first be obtained from dbx. The company shall not be liable for any consequential damage as a result of the product's use in any circuit or assembly.
  4. dbx reserves the right to make changes in design or make additions to or improvements upon this product without incurring any obligation to install the same additions or improvements on products previously manufactured.
  5. The foregoing is in lieu of all other warranties, expressed or implied, and dbx neither assumes nor authorizes any person to assume on its behalf any obligation or liability in connection with the sale of this product. In no event shall dbx or its dealers be liable for special or consequential damages or from any delay in the performance of this warranty due to causes beyond their control.

INTRODUCTION

Thank you for purchasing the dbx PS6 power supply. The PS6 power supply is designed to power up to six dbx PMCs. When combined with a dbx PMC personal monitoring system, the PS6 eliminates the need for multiple on-stage power strips and can help clean up on-stage wiring.

INCLUDED ITEMS

Before you get started, ensure the following items have been included:

  • PS6 Power Supply
    • 1 IEC Power Cable
    • 6 20' PMC Power Cables
  • Owner's Manual

The utmost care was taken while manufacturing your PS6. Everything should be included and in perfect working order. If anything is missing or damaged, contact the factory at once.

7

CONNECTION DIAGRAM
DBX PS6 - INCLUDED ITEMS - 1

flowchart
graph TD
    A["Power Supply"] --> B["Connect AC power cable"]
    B --> C["PS6"]
    C --> D["PMC16 PMC16 PMC16"]
    C --> E["PMC16 PMC16 PMC16"]
    C --> F["PMC16 PMC16 PMC16"]
    C --> G["PMC16 PMC16 PMC16"]

DESCRIPTION
1 2

3 4 dbx® PROFESSIONAL PROVINCE 3 2019 2020 2021 2022 2023 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 2035 2036 2037 2038 2039 2040 2041 2042 2043 2044 2045 2046 2047 2048 2049 2050 2051 2052 2053 2054 2055 2056 2057 2058 2059 2060 2061 2062 2063 2064 2065 2066 2067 2068 2069 2070 2071 2072

  1. POWER INDICATOR LED

This green LED indicates whether or not the PS6 is powered on.

  1. POWER OUTPUT CONNECTORS

Connect the included power cables to these output connectors for powering up to six dbx PMC devices.

  1. POWER INLET

Connect the included IEC power cable to this inlet to provide power to the PS6.

  1. FAN

This temperature controlled fan automatically turns on and off as needed.

SPECIFICATIONS

Input:

Connector: 1 IEC

Voltage: 100-240 VAC, 50-60 Hz

Outputs:

Connectors: 6 Barrel Jacks

Output Polarity: (Center Negative)

Voltage: 12 VDC

Current: 800 mA Maximum Per Output

Fan:

Type:

Temperature Controlled

Physical:

Dimensions: 2.2" (H) × 5.42" (W) × 5.82" (D)

Weight: 1.65 lbs (0.75 kg)

Shipping Weight: 3.9 lbs (1.77 kg)

8

Manual assistant
Powered by Anthropic
Waiting for your message
Product information

Brand : DBX

Model : PS6

Category : Power Supply