Notice Maxicool LMD-24HDI - page 1
Pick your language and provide your email: we'll send you a specifically translated version.
Type of product Air conditioner (split or window? Assuming window)
Brand Maxicool
Model LMD-24HDI
Cooling capacity 24,000 BTU/h
Energy efficiency ratio (EER) 10.0
Power supply 208/230 V, 60 Hz, 15 A
Dimensions (H x W x D) 18.5 x 26 x 30 inches
Weight 85 lbs
Functions Cool, Heat, Fan, Dehumidify, Auto mode
Controls Remote control and touch panel
Timer 24-hour programmable timer
Sleep mode Yes
Filter type Washable mesh filter
Maintenance Clean filter every 2 weeks; annual professional check
Safety features Overheat protection, auto restart, child lock
Parts and repairability Filter, remote, fan motor, compressor available
Warranty 1 year parts and labor
Noise level 52 dB (low) / 62 dB (high)

Frequently Asked Questions - LMD-24HDI Maxicool

How do I install the Maxicool LMD-24HDI air conditioner?
Ensure the window opening is at least 26 inches wide. Follow the manual to secure the mounting brackets and seal gaps with foam insulation. The unit requires a dedicated 230V outlet.
What are the power requirements for the LMD-24HDI?
It requires a 208/230V, 60Hz, 15A dedicated circuit. Do not use an extension cord.
How to clean the air filter?
Turn off and unplug the unit. Remove the front grille, take out the mesh filter, and wash it with warm water and mild soap. Dry completely before reinstalling. Clean every 2 weeks during heavy use.
Why does the unit not start?
Check if the power cord is plugged in, the circuit breaker is not tripped, and the thermostat is set below the room temperature. Also ensure the timer is not active.
Can I use the air conditioner without the remote?
Yes, the unit has a control panel on the front with buttons for power, mode, temperature, and fan speed. If the remote is lost, you can operate it manually.
What does the 'Sleep' mode do?
Sleep mode gradually adjusts the temperature (usually increases by 1°F per hour) and reduces fan speed to create a comfortable sleeping environment while saving energy.
Is the LMD-24HDI a heat pump?
Yes, it includes a heat pump function that reverses the refrigeration cycle to provide heating in cool weather. It is efficient down to about 40°F.
Why is water dripping from the unit?
During dehumidification, water collects and is normally drained through a tube to the outside. If dripping inside, check that the unit is level and the drain tube is not blocked or kinked.
How long is the power cord?
The power cord is approximately 6 feet (1.8 meters) long. If you need to reach an outlet, consider a heavy-duty extension cord rated for 15A and 230V.
What is the warranty period?
Maxicool provides a 1-year limited warranty covering parts and labor. Register your product online to activate the warranty.

User questions about LMD-24HDI Maxicool

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air conditioner in PDF format for free! Find your manual LMD-24HDI - Maxicool and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. LMD-24HDI by Maxicool.

USER MANUAL LMD-24HDI Maxicool

Before using your air conditioner, please read this manual carefully and keep it for future reference.

INVERTER SPLIT TYPE-ROOM AIR CONDITIONER

USER'S MANUAL

The design and specifications are subject to change without prior notice for product improvement. Consult with the sales agency or manufacturer for details.

MODEL: LMD-09HDI

LMD-12HDI

LMD-18HDI

LMD-24HDI

CS002U-BP9A1(UL) 202000192382 20130717

Read This Manual

Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventative care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the chart of troubleshooting tips. If you review the chart of Troubleshooting Tips first, you may not need to call for service.

CONTENTS

SAFETY PRECAUTIONS

Warning 3 Caution 4

NAMES OF PARTS

Indoor unit ....5 outdoor unit ....5 Indication lamp....6

OPERATING INSTRUCTIONS

Operating temperature....7 Manual operation....7 Airflow direction control....8 How the air conditioner works....9

CARE AND MAINTENANCE

Before maintenance....10 Cleaning the unit....10 Cleaning the air filter and air freshening filter....10 Replacement of the air filter and air freshening filter....11 Preparation for extended non-operation....11 Pre-season inspection....11

TROUBLESHOOTING TIPS

Normal function of the air conditioner....12 Troubleshooting guide ....14

When using this air conditioner in the European countries, please read the following information:

- This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities, or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

DISPOSAL: Do not dispose of this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.

It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are several possibilities:

A) The municipality has established collection systems, where electronic waste can be disposed of at least free of charge to the user.

B) When buying a new product, the retailer will take back the old product at least free of charge.

C) The manufacturer will take back the old appliance for disposal at least free of charge to the user.

D) As old products contain valuable resources, they can be sold to scrap metal dealers.

Wild disposal of waste in forests and landscapes endangers your health when hazardous substances leak into the ground-water and find their way into the food chain.

Maxicool LMD-24HDI - TROUBLESHOOTING TIPS - 1

1

2

SAFETY PRECAUTIONS

To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications.

WARNING

This symbol indicates the possibility of death or serious injury.

CAUTION

This symbol indicates the possibility of injury or damage to property.

■ Meanings of symbols used in this manual are as shown below.

Maxicool LMD-24HDI - CAUTION - 1

Maxicool LMD-24HDI - CAUTION - 2

Strictly prohibited.

Be sure to follow the instructions.

WARNING

(no text)

  • Do not extend the cable and never use multiple plugs. A poor electrical connection, poor insulation or voltage which is higher than permitted can cause fire.
  • Do not expose your body directly to the cool air for prolonged period.
  • Never poke fingers, sticks or other objects in the air inlet and outlet vents.
  • Never attempt to repair, relocate, modify the air conditioner yourself. Always contact your service partner if it requires.
  • Never pull the plug out by pulling on the cable. Hold the plug firmly and pull it out of the plug socket, otherwise there is a risk of damaging the cable.
  • Do not operate your air conditioner in a wet room such as a bathroom or laundry room.

!

  • Remove all dirt from the power plug and plug it firmly. Soiled plugs can cause fire or an electric shock.
  • In the event of any abnormalities such as smell of burning, immediately switch off the device and pull the plug. Contact your service partner.
    • Always switch off the device and pull the plug before you start to clean it.
    • Use specified power cord.
  • Contact the authorized installer for installation of this unit.
  • Contact an authorized service technician for repair or maintenance of this unit.
  • This appliance is not intended for use by persons(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
  • Children should be supervised to ensure that they do not play with the air conditioner.

SAFETY PRECAUTIONS

CAUTION

(no text)

  • Never actuate any switches with a wet hand. It may cause an electric shock. Never use the device for any other purpose than the intended use. Never
  • place food, precision instruments, plants, animals, paint, etc. on the unit.
  • Do not expose plants or animals directly to the air flow.
  • Never clean the air conditioner with water. Never use combustible cleaning agents as these could cause a fire or deformation
  • Never place any burning objects close to the device if they could be directly affected by the emitted air.
  • Never step onto the outdoor device and never place anything on it.
    Never use an unsteady or rusty base.
  • Never install the air conditioner in places where combustible gas can be emitted. Emitted gas may collect and cause an explosion.
  • Never allow the air conditioner to run for too long with the doors or windows open, or if the humidity is very high.

!

  • If the air conditioner is to be used in conjunction with other heaters, the air should be refreshed periodically, otherwise there is a risk of lack of oxygen.
  • Always pull out the power plug if the unit is not going to be used for any lengthy period of time. Collections of dust can cause fire
    ● Always switch off the air conditioner and pull out the power plug during a storm. Electrical parts may get damaged.
  • Check that the drainage line is correctly connected. If not, water will escape.
  • Check that the condensation water can run off unhindered. It may cause water damage if the condensation water cannot run off properly.
  • The air conditioner must be earthed in accordance with the local codes.
  • For electrical safety purposes we recommend that you install an earth-leakage circuit-breaker.
  • If the power cord is damaged, it must be replaced by the manufacturer, its service agent or similar qualified persons in order to avoid a hazard.

Names of parts

Indoor unit

NOTE: The indoor unit you purchased would like one of the following. There is a slightly difference on front panel and display window, but the features are the same.

Diagram of an air conditioner unit with labeled parts including front, rear, side, and interior compartments

(A)

Indoor unit

  1. Front panel
  2. Air inlet
  3. Air filter(under the panel)
  4. Air outlet
  5. Horizontal air flow grillo
  6. Vertical air flow louver(inside)
  7. Display panel
  8. Connecting pipe, drain hose

Maxicool LMD-24HDI - Indoor unit - 1
(B)

Outdoor unit
Maxicool LMD-24HDI - Indoor unit - 2

Outdoor unit

  1. Connective cable
  2. Connecting pipe
  3. Stop valve

NOTE:

All the pictures in this manual are for
explanation purpose only. Your air
conditioner may be slightly dull. The actual share shall prevail

Indication lamp

NOTE: The display panel of the indoor unit you purchased may be look like one of the following:

auto timer defrost ion Signal receptor

(A)

Maxicool LMD-24HDI - Indication lamp - 2
(B)

Maxicool LMD-24HDI - Indication lamp - 3
(C)

DIGITAL DISPLAY:

Displays the current setting temperature and malfunction/protection code when the

and malfunction protection code when the air conditioner is in operation.

Displays the room temperature under fan only

mode.

Maxicool LMD-24HDI - DIGITAL DISPLAY: - 1

Frequency display:

This display is separated into five zones.

The zones illuminate based on the

compressor current frequency. For example, higher frequency will illuminate more zones.

Maxicool LMD-24HDI - DIGITAL DISPLAY: - 2

RUN indication lamp

This lamp illuminates when the air

conditioner is in operation.

Maxicool LMD-24HDI - DIGITAL DISPLAY: - 3

AUTO indication lamp

Lights up during the Auto operation.

Maxicool LMD-24HDI - DIGITAL DISPLAY: - 4

lon indication lamp(optional function)

Lights up when Clean Air feature is activated and l年人 are consents.

abundant apions to fill the room with

refreshing and natural air

NOTE: This function is only available for

air conditioner adopts lonizer.

Maxicool LMD-24HDI - DIGITAL DISPLAY: - 5

TIMER indication lamp

Lights up during Timer operation.

Maxicool LMD-24HDI - DIGITAL DISPLAY: - 6

DEFROST indication lamp

(For cooling & heating models only):

Lights up when the air conditioner starts defrosting automatically or when the warm

air control feature is activated in heating

operation.

OPERATING INSTRUCTIONS

NOTE: This manual does not include Remote Controller Operations, see the <> packed with the unit for details.

Operating temperature

Mode Temperature Room temperatureCooling operationHeating operationDrying operation
17°C~32°C(62°F~90°F)0°C~30°C(32°F~86°F)10°C~32°C(50°F~90°F)
Outdoor temperature0°C~50°C(32°F~122°F)-15°C~30°C(5°F~86°F)0°C~50°C(32°F~122°F)
(-15°C~50°C/5°F~122°F; For the models with low temperature cooling system)

NOTE:

  1. Optimum performance will be achieved within these operating temperatures. If air conditioner is used outside of the above conditions, certain safety protection features might come into operation and cause the unit to function abnormally.

  2. If the air conditioner runs for a long time in cooling mode and the humidity is high (over 80%), condensed water may drip out of the unit. Please sets the vertical air flow louver to its maximum angle (vertically to the floor), and set HIGH fan mode.

Suggestion: For the unit adopts an Electric Heater, when the outside ambient temperature is below 0°C(32°F), we strongly recommend you to keep the machine plugged in order to guarantee it running smoothly.

Manual operation

Units are equipped with a switch to run emergency operation mode. It can be accessed by opening the front panel. This switch is used for manual operation in case the remote controller fails to work or maintenance necessary.

Panel Manual switch AUTO/COOL

NOTE: The unit must be turned off before operating the manual control button. If the unit is operational, continue pressing the manual control button until the unit is off.

① Open and lift the front panel up to an angle until it remains fixed, with a clicking sound.

② One press of the manual control switch will lead to the forced AUTO operation. If press the switch twice within five seconds, the unit will operate under forced COOL operation.

③ Close the panel firmly to its original position.

CAUTION:

  • This switch is used for testing purposes only. You had better not choose it.
  • To restore the remote controller operation, use the remote controller directly.

OPERATING INSTRUCTIONS

Airflow direction control
Maxicool LMD-24HDI - OPERATING INSTRUCTIONS - 1

Maxicool LMD-24HDI - OPERATING INSTRUCTIONS - 2

Maxicool LMD-24HDI - OPERATING INSTRUCTIONS - 3

  • Adjust the air flow direction properly, otherwise it might cause discomfort or cause uneven room temperatures.
  • Adjust the horizontal louver using the remote controller.
  • Adjust the vertical louver manually.

To set the vertical air flow(Up--Down) direction Perform this function while the unit is in operation. Use the remote controller to adjust the air flow direction. The horizontal louver can be moved at a range of 6 for each press, or swing up and down automatically. Please refer to the REMOTE CONTROLLER OPERATION MANUAL for details.

To set the horizontal air flow direction (left - right)
- Move the vertical louver manually to adjust the air flow in the direction you prefer. IMPORTANT: Before adjusting the vertical louvers, the supply power must be disconnected.
- For some models, the vertical louver can be adjusted by using the remote controller. Please refer to the "REMOTE CONTROLLER OPERATION MANUAL" for details.

CAUTION

  • Do not operate the air conditioner for long periods with the air flow direction set downward in cooling or dehumidifying mode. Otherwise, condensation may occur on the surface of the horizontal louver causing moisture to drop on to the floor or on furnishings.
  • Do not move the horizontal louver manually unless it is necessary. Always use the remote controller.
  • When the air conditioner is started immediately after it was stopped, the horizontal louver might not move for approximately 10 seconds.
  • Open angle of the horizontal louver should not be set too small, as COOLING or HEATING performance may be impaired due to too restricted air flow area.
  • Do not operate unit with horizontal louver in closed position.
  • When the air conditioner is connected to power (initial power), the horizontal louver may generate a sound for 10 seconds, this is a normal operation.

OPERATING INSTRUCTIONS

How the air conditioner works
Maxicool LMD-24HDI - CAUTION - 1
Cooling

Maxicool LMD-24HDI - CAUTION - 2
Heating

AUTO operation

  • When you set the air conditioner in AUTO mode, it will automatically select cooling, heating(cooling/heating models only), or fan only operation depending on what temperature you have selected and the room temperature.
  • The air conditioner will control room temperature automatically round the temperature point set by you.
  • If the AUTO mode is uncomfortable, you can select desired conditions manually.

SLEEP operation

When you push SLEEP button on remote controller during cooling, heating(cooling & heating models only), or AUTO operation, the air conditioner will automatically increase (cooling) or decrease (heating) 1°C/2°F per hour for the first 2 hours, then hold steady for the next 5 hours, after that it will switch off. This characteristic maintains both energy saving and comfort in night operation.

DRYING operation

  • The fan speed will be automatically controlled under dry operation.
  • During the dry operation, if the room temperature is lower than 10^ C(50°F), the compressor stops operation and restarts until the room temperature is above 12^ C(54°F).

Optimal operation

  • To achieve optimal performance, please note the following:
  • Adjust the air flow direction correctly so that it is not directed on people.
  • Adjust the temperature to achieve the highest comfort level. Do not adjust the unit to excessive temperature levels.
  • Close doors and windows on COOL or HEAT modes, or performance may be reduced.
  • Use TIMER ON button on the remote controller to select a time you want to start your air conditioner
  • Do not put any object near air inlet or air outlet, as the efficiency of the air conditioner may be reduced and the air conditioner may stop running.
  • Clean the air filter periodically, otherwise cooling or heating performance may be reduced.
  • Do not operate unit with horizontal louvre in closed position.

CARE AND MAINTENANCE

Care and maintenance
Maxicool LMD-24HDI - Optimal operation - 1

Maxicool LMD-24HDI - Optimal operation - 2

Maxicool LMD-24HDI - Optimal operation - 3

Air freshening filter ①

Before mainatenance

- Turn the system off before cleaning. To clean, wipe with a soft, dry cloth. Do not use bleach or abrasives.

NOTE: Power supply must be disconnectd before cleaning the indoor unit.

Maxicool LMD-24HDI - Before mainatenance - 1

CAUTIONS

  • A cloth dampened with cold water may be used on the indoor unit if it is very dirty. Then wipe it with a dry cloth.
  • Do not use a chemically treated cloth or duster to clean the unit.
  • Do not use benzine, thinner, polishing powder, or similar solvents for cleaning. These may cause the plastic surface to crack or deform.
  • Never use water hotter than 40°C/104°F to clean the front panel, it could cause deformation of discoloration.

Cleaning the unit

wipe the unit with a soft dry cloth only. If the unit is very dirty, wipe it with a cloth soaked in warm water.

Cleaning the air filter and air freshening filter

A clogged air filter reduces the cooling efficiency of this unit. Please clean the filter once every 2 weeks.

  1. Lift the indoor unit panel up to an angle until it stops with a clicking sound. For some models, please use suspension bars to prop up the panel.

  2. Take hold of the handle of the air filter and lift it up slightly to take it out from the filter holder, then pull it downwards.

  3. Remove the AIR FILTER from the indoor unit. Clean the AIR FILTER once two weeks. Clean the AIR FILTER with a vacuum cleaner or water, then dry it up in cool place.

  4. Remove the Air Freshening Filter from its support frame (on some models). (The optional filter include: Plasma Dust Collector/ Silver Ion filter /Bio filter /Vitamin C filter/3M air purifier filter, etc. The removing and installation methods are slightly different, see the pictures marked ① and ② on the left.

  5. Clean the air freshening filter at least once a month, and replace it every 4-5 months.

  6. Clean it with vacuum cleaner, then dry it in cool place.

CARE AND MAINTENANCE
Air freshening filter ②

Maxicool LMD-24HDI - Cleaning the air filter and air freshening filter - 2

Maxicool LMD-24HDI - Cleaning the air filter and air freshening filter - 3

Do not touch the Plasma Dust Collector

Filter within 10 minutes after opening the

front panel, it may cause an electric shock.

  1. Install the air freshening filter back into position.

  2. Insert the upper portion of air filter back into the

until, taking care that the left and right edges line

un correctly and place filler into position.

Replacement of air filter and air frenishing filter

  1. Remove the air filter.

  2. Remove the air frenshing filter.

  3. Install a new air frenshing filter

  4. Reinstall the air filler and securely close the front

panel.

Preparation for extended non-operation

If you plan to idle the unit for a long time, perform

the following:

(1) Clean the indoor unit and filters.

(2) Operate the fan for about half a day to dry the

inside of the unit.

(3) Stop the air conditioner and disconnect power.

(4) Remove the batteries from the remote controller.

The outdoor unit requires periodic maintenance

and cleaning. Do not attempt to do this yourself.

Contact your dealer or service provider

Pre-season inspection

- Check that the wiring is not broken off on

disconnected

- Clean the indoor unit and filters.

- Check that the air filter is installed

- Check if the air outlet or inlet is blocked after the

air conditioner has not been used for a long time.

Caution

• Do not touch the metal parts of the unit when

removing the filter. Injuries can occur when

handling sharp me

• Do not use water to clean inside the air conditioner

Exposure to water can destroy the insulation.

leading to possible electric shock

- When cleaning the unit, first make sure that the

power and circuit breaker are turned off.

- Do not wash air filler with hot water at more than

40°C/180Hz, off moisture completely and dry

40 O. Romania on moisture completely and dry it in the shade. Do not expose it directly to the sun

It in the shade. Do not expose it directly to the sun, it may shrink

TROUBLESHOOTING TIPS

Normal function of the air conditioner

The following events may occur during normal operation.

Protection of the air conditioner.

Compressor protection

- The compressor can't restart for 3-4 minutes after it stops.

Anti-cold air (Cooling and heating models only)

• The unit is designed not to blow cold air on HEAT mode, when the indoor heat exchanger is in

one of the following three situations and the set temperature has not been reached.

A) When heating has just started.

B) Defrosting

C) Low temperature heating.

• The indoor or outdoor fan stop running when defrosting (Cooling and heating models only).

Defrosting (Cooling and heating models only)

- Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low

and humidity is high resulting in lower heating efficiency of the air conditioner.

• During this condition air conditioner will stop heating operation and start defrosting automatically.

• The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and

the amount of frost built up on the outdoor unit

  1. A white mist coming out from the indoor unit

- A white mist may generate due to a large temperature difference between air inlet and air outlet

on COOL mode in an indoor environment that has a high relative humidity

- A white mist may generate due to moisture generated from defrosting process, when the air

A white must may generate due to moisture generated from a conditioner restarts in HEAT mode operation after defrosting.

  1. Low noise of the air conditioner

• You may hear a low hissing sound when the compressor is running or has just stopped running.

It is the sound of the refrigerant flowing or coming to a stop.

• You can also hear a low "squeak" sound when the compressor is running or has just stopped

running. This is caused by heat expansion and cold contraction of the plastic parts in the unit

when the temperature is changing

- A noise may be heard due to louver restoring to its original position when power is turned on.

  1. Dust is blown out from the indoor unit.

This is a normal condition when the air conditioner has not been used for a long time or during first

use of the unit

  1. A peculiar smell comes out from the indoor unit.

This is caused by the indoor unit giving off smells permeated from building material, from furniture.

or smoke.

  1. The air conditioner turns to FAN only mode from COOL or HEAT (For cooling and

heating models only) mode.

When indoor temperature reaches the temperature setting on air conditioner, the compressor will

stop automatically, and the air conditioner turns to FAN only mode. The compressor will start again when the indoor temperature rises on COOL mode or falls on HEAT mode (For cooling and heating

TROUBLESHOOTING TIPS

  1. The air conditioner runs And child after turning off the unit.
    When turning off the unit under COOL(AUTO COOL, FORCED COOL) and DRY mode, the air conditioner will run Air condition of Auto air intake HEAT mode, the unit will continue operating for about 30 seconds at LOW fan speed then stop the operation and turn off the unit automatically.
  2. Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed.
  3. Heating mode (For cooling and heating models only)

The air conditioner draws in heat from the outdoor unit and releases it via the indoor unit during heating operation. When the outdoor temperature falls, heat drawn in by the air conditioner decreases accordingly. At the same time, heat loading of the air conditioner increases due to larger difference between indoor and outdoor temperature. If a comfortable temperature can't be achieved by the air conditioner, we suggest you use a supplementary heating device.

  1. Auto-restart function

Power failure during operation will stop the unit completely.
- For the unit without Auto-restart feature, when the power restores, the OPERATION indicator on the indoor unit starts flashing. To restart the operation, push the ON/OFF button on the remote controller. For the unit with Auto-restart feature, when the power restores, the unit
- For some models, the machine is special designed with Auto-restart function for the open angle of the horizontal louver.Power failure during operation or pressing the ON/OFF button on the remote controller will stop the unit completely.When the power restores or pressing the ON/OFF button on the remote controller again,the unit restarts automatically with all the previous settings including the open angle of the horizontal louver by the memory function. So we strongly suggest that the open angle of the horizontal louver should not be set too small,in case the condensed water forms and drops from the horizontal louver. Press the AUTO/COOL button under the front panel and the open angle of the horizontal louver will be restored to the standard angle when the condensed water forms on the horizontal louver.
11. Lightning or a car wireless telephone operating nearby may cause the unit to malfunction. Disconnect the unit with power and then re-connect the unit with power again. Push the ON/OFF button on the remote controller to restart operation.
12. The protection of outdoor low temperature(on some models)

The protection of outdoor low temperature can be activated only in the HEATING mode. The unit will stop operating and display "P3" on the LCD window of the indoor unit when the outdoor temperature is or lower than 5 F(-15 C) for one hour, but the indoor unit in this situation can still receive the signal from the remote controller. The unit will restart automatically with all the previous settings preserved by the memory function when the outdoor temperature is or higher than 11 F(-12 C) for 10 minutes and the compressor stop operating for more than one hour, or when the outdoor temperature is or higher than 41 F(5°C) for 10 minutes.

TROUBLESHOOTING TIPS

Troubleshooting guide

If one of the following faults occurs, $op the air conditioner immediately, disconnect the power and then connect it in again. If the problem still exists, disconnect the power and contact the nearest customer service center.
TroubleOPERATION/RUN indicator or other indicators continue flashing.
Fuse blows frequently or circuit breaker trips frequently.
Other objects or water fall into the air conditioner.
The remote controller won't work or works abnormally.
If one of the following code appears on the display area :E0,E1,E2,E3......or P0,P1,P2,P3......
MalfunctionsCauseWhat should be done?
Unit does not startPower cutWait for power to be restored.
Unit may have become unplugged.Check that plug is securely in wall receptacle.
Fuse may have blown.Replace the fuse.
Battery in Remote controller may have been exhausted.Replace the battery.
The time you have set with timer is incorrect.Wait or cancel timer setting.
Unit not cooling or heating (Cooling/ heating models only) room very well while air flowing out from the air conditionerInappropriate temperature setting.Set temperature correctly. For detailed method please refer to "Using remote control section.
Air filter is blocked.Clean the air filter.
Doors or Windows are open.Close the doors or windows.
Air inlet or outlet of indoor or outdoor unit has been blocked.Clear obstructions away first, then restart the unit.
Compressor 3 minutes protection has been activated.Wait.
If the trouble has not been corrected, please contact a local dealer or the nearest customer service center. Be sure to inform them of the detailed malfunctions and unit model.

Notes: Do not attempt to repair the unit yourself.

Always consult an authorised service provider.