Whynter

SNO ARC-13W - Air conditioner Whynter - Free user manual and instructions

Find the device manual for free SNO ARC-13W Whynter in PDF.

📄 29 pages English EN Download 💬 AI Question 10 questions ⚙️ Specs
Notice Whynter SNO ARC-13W - page 5
Pick your language and provide your email: we'll send you a specifically translated version.
Product Type Portable Air Conditioner
Model SNO ARC-13W
Brand Whynter
Cooling Capacity 13,000 BTU/h
Voltage / Frequency 115 V / 60 Hz
Amperage 10.5 A
Power Consumption (Cooling) 1,200 W
Energy Efficiency Ratio (EER) 10.8
Moisture Removal 3.2 pints/hr
Airflow 410 CFM
Noise Level 52 dB
Dimensions (W x D x H) 18.5 x 15.5 x 29.5 in
Weight 68 lbs
Refrigerant Type R-410A
Modes Cool, Fan, Dehumidify
Fan Speeds 3 (Low, Medium, High)
Remote Control Yes (Included)
Timer 24-hour programmable
Filter Type Washable, Reusable
Filter Cleaning Interval Every 2 weeks to monthly
Exhaust Hose Length 5.5 ft
Window Kit Included Yes (adjustable)
Safety Features Overload protection, auto restart
Warranty 1 year limited

Frequently Asked Questions - SNO ARC-13W Whynter

How do I clean the air filter?
Turn off and unplug the unit. Remove the filter grille, take out the filter, and wash it with warm water and mild detergent. Let it dry completely before reinstalling. Clean every 2 weeks for optimal performance.
What does error code E1 mean?
E1 indicates a room temperature sensor malfunction. Check if the sensor is properly connected and clean. If the issue persists, contact Whynter support.
How do I set the timer?
Press the Timer button on the remote or control panel. Use the +/- buttons to set the desired hours (1-24). Press Timer again to confirm. The unit will turn on/off automatically.
Why is water leaking from the unit?
If using in dehumidify mode, the internal tank may fill up. Check the continuous drain connection or empty the tank manually. In cool mode, ensure the unit is level and the drain plug is tight.
Can I use an extension cord?
It is not recommended. Use a dedicated 115V outlet rated for at least 15A. Extension cords may cause voltage drop and overheating.
How do I install the window kit?
Slide the window kit to fit your window width. Secure it in place, attach the exhaust hose to the unit and the window kit adapter. Ensure a tight seal to prevent hot air from entering.
Why is the unit not cooling?
Check if the filter is dirty, ensure the window is closed, and the exhaust hose is not blocked. Also confirm the unit is in cool mode and the set temperature is below room temperature.
How do I use the continuous drain?
Locate the drain outlet at the back. Attach a garden hose (3/4 inch) and route it to a floor drain or bucket. Ensure the hose is not kinked. Use only in dehumidify or heat pump mode (if applicable).
The remote control is not working. What should I do?
Replace the batteries (2 AAA) and ensure the remote is pointed at the receiver. Check for obstructions. If still not working, try using the control panel on the unit.
How often should I service the air conditioner?
Clean the filter monthly. Inspect the exhaust hose and window seal annually. Have a professional check the refrigerant lines and compressor every 2-3 years if needed.

User questions about SNO ARC-13W Whynter

0 question about this device. Answer the ones you know or ask your own.

Ask a new question about this device

The email remains private: it is only used to notify you if someone responds to your question.

No questions yet. Be the first to ask one.

Download the instructions for your Air conditioner in PDF format for free! Find your manual SNO ARC-13W - Whynter and take your electronic device back in hand. On this page are published all the documents necessary for the use of your device. SNO ARC-13W by Whynter.

USER MANUAL SNO ARC-13W Whynter

Another Whyler Innovation

WHYNTER SNO PORTABLE AIR CONDITIONER

MODEL#: ARC-13W/S

Whynter SNO ARC-13W - WHYNTER SNO PORTABLE AIR CONDITIONER - 1

natural_image Exterior view of a modern electric heater with ventilation grilles and a control panel (no visible text or symbols)

Whynter SNO ARC-13W - WHYNTER SNO PORTABLE AIR CONDITIONER - 2

Thank you for choosing the Whynter SNO portable air conditioner. You have bought one of the best portable air conditioners available today. Follow the instructions given in this booklet to obtain the very best performance from your portable air conditioner and take full advantage of the many advance features that your portable air conditioner offers you. We wish you many years of enjoyable use.

Please keep this user manual in a safe place for future reference.

DISPOSAL

Whynter SNO ARC-13W - DISPOSAL - 1

natural_image Symbol of a trash bin crossed with diagonal lines, representing no waste or discharge (no text or labels)

This symbol on the product or its packaging indicates that the appliance cannot be treated as normal domestic trash, but must be handed in at a collection point for recycling electric and electronic appliances. Your contribution to the correct disposal of this product protects the environment. Further information about the recycling of this product can be obtained from your local municipal authority.

Fig. 1 4 6 8 4 1 3 2 7 5 9

  1. Control panel

  2. Pull handle

  3. Air outlet grille

  4. Air filter with grille

  5. Drain plug

  6. Outdoor air inlet

  7. Outdoor exhaust

  8. Top handle

  9. Power cord

Whynter SNO ARC-13W - DISPOSAL - 3

natural_image Diagram of household air conditioner system with cooling fans and condenser placement (no text or labels)

Fig. 2 Incorrect setu
p

Whynter SNO ARC-13W - DISPOSAL - 4

natural_image Diagram of a staircase with a car at the base, showing structural components (no text or symbols)

Fia. 3
Correct setup

Whynter SNO ARC-13W - DISPOSAL - 5

SAFETY PRECAUTIONS

  • Ensure curtains or other objects are not obstructing the air inlet filters. (Fig.2)
  • Do not bend or crush the exhaust hose while in use. (Fig.2)
  • Transport the unit in an upright position only, or leave it in an upright position for at least 2 hours before first use.
    • Always place the unit on even and hard surface.
  • The power cord is UL listed. It has a built-in L.C.D.I. (leakage, current, detection, interruption) circuit breaker for added safety. If the power supply is interrupted, press the reset button to reconnect the unit to power source.
    • Make sure this unit is connected to a correctly grounded power supply outlet. Do not use an extension cord.
  • Do not turn this unit on and off by plugging and unplugging. Always use the ON/OFF switch.
  • Do not sit or place objects on the unit.
  • Always allow air flow around the portable air conditioner for at least 20'. Do not use this unit inside closets, cabinets and/or cramped spaces between furniture.
    • To avoid the risk of shock, the product should never be used in bathrooms, shower rooms, or in any other steamy or wet areas.
  • Do not operate this unit without the air filter.
  • Do you use harsh chemicals to clean the filter. Dry thoroughly before inserting the filter into the unit
  • This unit is optimized to operate in an ambient temperature of 64^ - 100^ .
  • Do not repair, disassemble and/or modify the unit by yourself.
  • An opening in a window or wall is required to accommodate the exhaust hose (window kit supplied) to exhaust the hot air from the back of the unit.
  • Do not add extra length to the exhaust hose by more than a total length of 9'. This will reduce the cooling efficiency of the portable air conditioner.
    • Always turn off the portable air conditioner when cleaning the air filter, and transporting.
  • At the end of each season, all water must be drained from the unit and filter must be cleaned before storage.
  • Do not use an excessively wet cloth, industrial solvents, oil-based products to clean this portable air conditioner.

THE MANUFACTURER DISCLAIMS ANY RESPONSIBILITY IF THE ABOVE INSTRUCTIONS ARE NOT FOLLOWED.

WINDOW KIT INSTALLATION
Part 1 Part 2 Part 3 Part 4

Whynter SNO ARC-13W - SAFETY PRECAUTIONS - 2

In order for this portable air conditioner to work properly, the hot air from the back of the unit must be vented to the outside. Please follow the instructions below for window kit installation.

  1. Extend the exhaust hose (Part 1) at least 6" and insert it to the outdoor exhaust outlet at back of the unit.
  2. Attach the round connector (Part 3) to the other end of the hose.
  3. Open your window and place the adjustable window slide bar (Part 2) to the opening of the window. Expand the bar so it fits tightly horizontally.
  4. Lower the window so the bar fits to the opening of the window tightly.
  5. Attach the hose with the round connector to the round opening of the window slide bar.
  6. When the air conditioner is not in use, remove the hose from the window slide bar and place the round cover (Part 4) to the opening of the bar.
  7. For non-fixed openings, such as doors or sliding doors that may need to be opened or closed, attach the rectangle connector (Part 5) to the end of the hose and place the connector to the opening of the door.

INSTALLATION

Whynter SNO ARC-13W - INSTALLATION - 1

natural_image Diagram of a staircase with a solar panel attached, showing structural components (no text or symbols)

135 mm min. 400 mm

Whynter SNO ARC-13W - INSTALLATION - 3

natural_image Simple grayscale illustration of a door handle with a circular hole and horizontal line (no text or symbols)

Fig. 4

When you use this air conditioner unit, hot air must be exhausted out of the room to complete the air exchange of the condenser. When the unit is operating in fan-only mode, no exhaust is required.

Exhaust hose Installation

The exhaust hose must be installed onto the unit.

  1. Pull out about 6" of one end of the exhaust hose.
  2. Screw the exhaust connector on the exhaust hose in a clockwise motion.
  3. Snap the exhaust connector in place in the back of the unit.
  4. Only extend the exhaust hose to the necessary length.

Window Installation (Fig. 4)

  1. Make sure the exhaust hose is properly installed onto the portable air conditioner.
  2. Open window or sliding door for approximately 5" (130 mm)
  3. Adjust the length of the window kit to the same length and width of the opening of the window or the sliding door. Cut the window piece if necessary to fit the length of your window or sliding door.
  4. Place the window kit on your window or sliding door, with the exhaust hole as near to the portable air conditioner as possible.
  5. Close the window or sliding door, on the window kit. For long term installation, you may screw the window kit into your window frame.
  6. Adjust the length of the exhaust hose and mount the window kit adaptor to the window kit.

NOTE: When using the window kit on a window or sliding door it will cause the window or sliding door not to be properly closed and locked. Additional security measurements maybe needed.

Wall Installation

  1. Make sure the exhaust hose is properly installed onto the portable air conditioner.
  2. Make a hole of 5.3" (135mm) diameter in the wall.
  3. Insert as much as exhaust hose as needed through the hole.
    NOTE: Make sure to have a qualified professional to make the hole to avoid the possibility of injury or damage to the structure. Make sure that the hole is covered when it is not used by the portable air conditioner.

CONTROL PANEL

1 2 3 4 5 6

Fig. 5

  1. Stand-by or Comfort (automatic) function button
  2. Red - Stand-by
  3. Green - Air conditioner is on
  4. Orange - On and/or off program is enabled
  5. Green - Automatic function is on
  6. Remote control signal reception button

OPERATIONS

SWITCHING ON THE AIR CONDITIONER

The portable air conditioner can be switched on by the remote control or by pressing the On/Off button on the control panel. Without using the remote control, the unit can only be switched on the Comfort (automatic) function. To transmit signals from the remote control to the air conditioner, point the front part of the remote handset towards the control panel on the air conditioner. Reception of the signal is confirmed by a beep. The maximum signal transmission distance is approximately 8 meters / 26 feet.

NOTE:

  • Other appliances in the same room controlled by a remote control (TV, radio, stereo, etc.), may cause interferences.
  • Electronic and fluorescent lamps may interfere with the signal transmissions between the remote control and the air conditioner.
  • Remove the batteries if the remote control is not used for long periods.

Whynter SNO ARC-13W - NOTE: - 1

natural_image Diagram of a handheld device with two batteries and a central internal component, no text or symbols present

Fig. 6

INSTALLING BATTERIES

• Only use 2 LR03 1.5V Batteries (included) in the remote control.
• Always change both batteries at the same time.
- To insert the batteries, open the flap on the back of the remote control. Strictly adhere to the polarity signs on the bottom of the battery housing, close the flap once the batteries have been inserted (Fig. 6).

REMOTE CONTROL

D2 D3 D4 D5 D1 D6 D7 D8 8830 D9 T1 T10 T2 T3 T5 T6 T4 T7 T8 T11 T9 T10

BUTTONSDISPLAYS
T1 On/Off D1 Fan speed or the automatic fan function mode (AUTO)
T2 Comfort button (automatic) D2 Heating (not enabled)
T3 Night Comfort button D3 Cooling function indicator
T4 Function Mode selector D4 Dehumidifying function indicator
T5 Fan Speed selector D5 Outdoor air outlet enabled (not enabled)
T6 Set Time and Program button D6 Night comfort function indicator
T7 Increase (+) / Decrease (-) Temperature / Time value buttonD7 Automatic function indicator
T8 Button not enabled D8 First program indicator
T9 Button not enabled D9 Second program indicator
T10 Reset button D10 Temperature (thermometer), hour and minutes (H M) indicator
T11 Enable Program button

The remote control has a sliding cover. Without pulling the cover down, the remote control can turn On/Off the unit, start or stop the Comfort (automatic) and Night Comfort functions only.

65 T1

Fig. 8
Fig. 9

AUTO T2

SWITCHING ON/OFF THE AIR CONDITIONER (Button T1)

Press the T1 button to switch on/off the air conditioner (Fig. 8).

The control system of the air conditioner stores the previously programmed data in its memory; therefore, the settings are not lost when the air conditioner is switched off.

When the red LED (2) on the control panel is illuminated, this indicates that the air conditioner is switched off.

When the green LED (3) on the control panel is illuminated, this indicates that the air conditioner is switched on.

COMFORT (AUTOMATIC) FUNCTION (Button T2)

Press the T2 button (Fig. 9), the air conditioner will automatically run to achieve the optimum comfort temperature of (72°F/22°C.)

When the Comfort function is on, the compressor will stop when the temperature is below 72^ and the compressor will start when the temperature is above 72^ .

T3 F i g . 1 4 T4 T7

NIGHT COMFORT BUTTON (Button T3)

Press the T3 button to activate the night comfort function (Fig.14). In this function, the air conditioner gradually increases the set temperature in cooling mode, decreases the noise level and conserves energy at night time. In cooling mode, the set temperature is maintained for an hour after the Night Comfort function has been activated. In the next hour, the temperature is gradually increased by up to 3°F. After the second hour, the temperature remains the same.

To activate the a Night Comfort function, first select the desired function mode by pressing the T4 button, program the desired temperature settling by pressing the T7 (+ / -) button, then press the T3 Night Comfort button. The fan speed of the Night Comfort function is at the lowest and cannot be changed.

The Night Comfort can be cancelled at any moment (ideally when you wake up) by pressing the T3 button. The temperature and fan speed settings (programmed before the Night Comfort function was activated) will be restored.

65 T4

Fiq. 10 Fi

T4

q. 11

COOLING/ DEHUMIDIFICATION ONLY/ FAN ONLY FUNCTION (Button T4)

Cooling Mode

In this mode, the air conditioner cools and dehumidifies the room. To activate this function, press the T4 Function Mode Selector button until the FROST symbol appears on the display (Fig. 10). When this function mode is set, the compressor will start in approximately 3 minutes. Subsequently, set the desired temperature and fan speed (refer to the appropriate sections). Please note that when switching function mode, there will be an approximately 3 minutes transition time.

Dehumidifying Only Mode

In this mode, the air conditioner only dehumidifies the room, the compressor will activate intermittently depending on the ambient temperature. To activate this function, press the T4 Function Mode Selector button until the DROPLET symbol appears on the display (Fig. 11). When this function mode is set, the fan speed settings cannot be changed and it is automatically set to minimum. Please note that when switching function mode, there will be an approximately 3 minutes transition time.

T4 FAN SET + -

Fig. 12

Fan Only Mode

In this mode, only the fan of the air conditioner runs and circulates the air in the room. To activate this function mode, press the T4 Function Mode Selector button until just the FAN symbol appears on the display (Fig.12). Subsequently, set the desired fan speed. Please note that when switching function mode, there will be an approximately 3 minutes transition time.

T5

Fig. 13

FAN SPEED CONTROL (Button T5)

Press the T5 button to set the fan speed. To change the fan speed, press this button repeatedly to achieve the following sequence (Fig 13):

- Low, Medium, High and Automatic When set in Automatic fan speed mode, the air conditioner automatically adjusts the fan speed. In this mode, the greater the difference between the ambient temperature and the set temperature, the higher the fan speed. The fan speed is automatically reduced as the ambient temperature gradually reaches the set temperature.

SETTING THE FUNCTION PROGRAM MODES

This air conditioner has two distinct function programs that can be used to stop and start the appliance at certain times (for example the air conditioner can be programmed to start just before you get home so when you arrive home, the temperature is pleasant). If you wish to use there functions, it is necessary to set the exact time and the function programs to run at the desired times.

08 T6 T7 33 T6 T7

Fia. 15

SETTING THE CURRENT TIME ON THE REMOTE CONTROL (Button T6-T7)

To set the exact time, proceed as follows (Fig.15):

  • Press the T6 Set time and Program button repeatedly until the hour (H) symbol appears on the display.
  • Press the T7 +/- - button to increase or decrease the hour (0-23) until the exact hour value is displayed.
  • Press the T6 Set time and Program button again until the minute (M) symbol appears on the display.
  • Press the T7 +/- button to increase or decrease the minute (0-59) until the exact minute value is displayed.

12 1030 T6 T7 1830 T6 T7

Fig. 16

Setting the On/Off times of the 1^st and 2^nd Function Programs (PROGR. 1 and PROGR.2)

To set the air conditioner On/Off times for the two programs proceed as follows (Fig. 16):

• To set the start time of the 1 ^st program

- Press the T6 Set Time and Program button repeatedly until the PROGR.1 (D8) symbol with a vertical line on the left appears on the display (the start time of the 1^st program) is displayed.

- Press the T7 + /- button to set the time (0:00 - 23:30) when you want the 1^st program to start. The timer interval is 30 minutes.

• To set the stop time of the 1 ^st program

- Press the T6 Set Time and Program button again. PROGR.1 (D8) symbol with a circle on the right (the stop time of the 1^st program) will appear on the display.

- Press the T7 + /- button to set the time (0:00 - 23:30) when you want the 1^st program to stop. The timer interval is 30 minutes.

• To set the start time of the 2nd program
- Press the T6 Set Time and Program button repeatedly until the PROGR.2 (D9) symbol with a vertical line on the left appears on the display (the start time of the 1^st program) is displayed.
- Press the T7 + /- button to set the time (0:00 - 23:30) when you want the 2nd program to start. The timer interval is 30 minutes.
• To set the stop time of the 2nd program
- Press the T6 Set Time and Program button again. PROGR.2 (D9) symbol with a circle on the right (the stop time of the 1^st program) will appear on the display.
- Press the T7 + /- button to set the time (0:00 – 23:30) when you want the 2nd program to stop. The timer interval is 30 minutes. To active one or both function programs, press the T11 Enable Program button. To return to normal function mode, press the T6 button repeatedly until the program symbols disappear from the display.

T11 12c 12c 1

Fig. 17

ENABLING AND DISABLING THE FUNCTION PROGRAMS (Button T11)

The function program(s) (either one or both) can be enabled or disabled (Fig. 17).

  • Press the T11 Enable Program button once and the 1^st program (D8) is enabled. Press the T11 button again, the 2^nd program (D9) is enabled.
  • Press the T11 button again, the 1^st and 2^nd programs (D8 & D9) are enabled.
  • Press the T11 button again, both programs are disabled.

AUTO 1 1/2 8828 1 2/3 T10

Fig. 18

RESETTING ALL REMOTE CONTROL FUNCTIONS (Button T10)

Press the T10 button to reset all remote control settings including timer and temperature settings (Fig. 18).

Whynter SNO ARC-13W - RESETTING ALL REMOTE CONTROL FUNCTIONS (Button T10) - 1

natural_image Close-up of a mechanical component with internal ribbed structure and two vertical arrows indicating direction (no text or symbols)

Fig. 19

CONTROLLING THE AIR FLOW DIRECTION

The direction of the airflow can be controlled vertically by moving the louvers up or down (Fig. 19).

HOW TO MANAGE THE AIR CONDITIONER WITHOUT THE REMOTE CONTROL

If it is not possible to use the remote control either because it was lost, has malfunctioned or the batteries are flat, the air conditioner can only be used in Comfort (automatic) mode by pressing the stand-by button (1) on the control panel for 5 seconds. When all of the LEDs on the control panel start to flash, this indicates that Comfort function has been enabled. To restore the normal remote control function, press any button on the remote control.

TRANSPORTATION

Whynter SNO ARC-13W - TRANSPORTATION - 1

natural_image Exterior view of a portable electric heater with ventilation grille and cooling fan (no text or symbols visible)

Fig. 20

The air conditioner is equipped with wheels and handles for easy portability. Before moving the air conditioner, proceed as follows:

  • Switch off the air conditioner and disconnect the plug from the power outlet
  • Drain water by removing the drain plug.
  • Always transport the air conditioner in an upright position only.

For short distances, use the top handle (Part 8). For greater distances, use the pull handle (Part 2) on the front of the air conditioner.

  • Pull the handle belt from the housing (Fig. 20).
  • Move the air conditioner as desired.
  • Reposition the pull handle back into its housing.

MAINTENANCE

Whynter SNO ARC-13W - MAINTENANCE - 1

CLEANING THE AIR FILTER

To ensure the air intake is filtered properly and to assure that your air conditioner runs efficiently, it is crucial to clean the air filters regularly.

When the air conditioner has been in use for a certain amount of time, the green LED (3) on the control panel (Fig. 5) will start to flash indicating that it is time to clean the air filters.

• Press the stand-by button to switch off the air conditioner. Remove the air filters housed in the air intake grilles on each side.
• Press the grips to release the air grilles and pull the filters frames up to remove from the frame (Fig. 22 & 23).
- Use a vacuum cleaner or tap lightly to remove loose dust and dirt from the filters. Then rinse them thoroughly under warm or cold running water (no hotter than 100F.)

• Dry thoroughly before re-inserting the filters.

Whynter SNO ARC-13W - CLEANING THE AIR FILTER - 1

WARNING! Never operate the air conditioner without the filters in place.

CLEANING THE AIR CONDITIONER

  • Always switch off the air conditioner and disconnect the plug from the power supply outlet before cleaning the air conditioner.
  • Use a soft damp cloth to wipe the body of the air conditioner.
  • Never use harsh chemicals, oil-based products, detergents, chemically treated cloths or other cleaning solutions. These could possibly damage the body of the air conditioner.

END OF SEASON STORAGE

  • Switch off the air conditioner and disconnect the plug from the power supply outlet before cleaning the air conditioner.
  • Clean the air filters
  • Drain the condensed water COMPLETELY
  • On a warm day, turn on the Fan only mode for a couple of hours so that the inside can dry out completely.
  • It is recommended that the air conditioner be put back into its original carton for storage.
  • Do not stack heavy objects on top of the air conditioner.
    • Make sure to store the remote control with the air conditioner.

TROUBLESHOOTING

ProblemPossibleCausesSolutions
The portable air conditioner does not turn onThere was a power failureRestore the power supply
The automatic switch, line fuse, or breaker has been trippedFlip the switch / change the fuse / turn the breaker back on. Also note that you may have too many appliances drawing power on one circuit, so you may need to move the other appliances to another circuit
The power supply voltage is too lowMove the unit onto another circuit with the correct voltage
The power cord is damagedCall for service. Only authorized personnel should replace damaged power cord or power plug
The LCDI plug for the unit is trippedPress the Reset button on the LCDI plug
The unit turns on, but the compressor does not turn on (the fan runs but the unit is not cooling)The room temperature is outside of the operational tolerances of the unitThis unit is designed to work in ambient temperatures of 64°F to 100°F
The Cooling mode is not onPress the Function Mode (T4) button until the Cooling icon (D3) is shown on the remote control. Make sure that the reception of the signal is confirmed by a beep.
The compressor has not turned on yet because of its time delayGive the compressor 3 minutes to turn on after the Cooling mode has been selected
The set temperature is too highSet the air conditioner to a lower temperature
The internal water reservoir is fullEither manually drain the water or allow the unit to exhaust the water itself. Then cooling will resume
The air coming out of the unit is not very cold, or the airflow volume is weakThe filters are dirty or obstructedClean the filters
The air intake is obstructedMake sure there is at least 20" of clearance from the air intakeMake the length of the exhaust hose is as short as possible
The exhaust is obstructedThe unit is set in dehumidifying or fan modeThe unit is set to low fan speedCheck for and remove any obstructionsSet the unit in cooling modeSet the unit to a higher fan speed
The unit has worked for a long time, but the room is not cold enoughWindows or doors are openThere are too many people in the roomThere is direct sunshine into the roomThe room is a kitchen, with many heat-producing appliancesThere is a server in the roomThe room is too largeThere are many electrical appliances in the roomClose all windows and doors into the room when the unit is coolingYou may need additional cooling or another air conditionerClose curtains and blinds and try to minimize the amount of direct sunlight into the roomYou may need additional cooling or another air conditionerYou may need additional cooling or another air conditionerYou may need additional cooling or another air conditionerYou may need additional cooling or another air conditioner
The unit is very noisy The unit is not levelThe surface underneath the unit is unevenMake sure the unit is levelMove the unit to a location with a level and hard floor
The unit is leaking water onto the floorThe unit is tilted, or is not levelThe water tank is fullMake use the unit is levelDrain water from the drain plug at the back of the air conditioner

TECHNICAL DATA

Cooling capacity 13,000 BTU
Recommended room size* 450 – 500 sq. ft.
E.E.R. – Energy efficiency rate 11.06
Power supply 115v/ 60Hz
Maximum power input 1175 W
Maximum input 10.21 Amp
Dehumidifying capacity 43 Pts / Day
Function programs 2
Thermostat 64F - 86F
RefrigerantR-22
CompressorRotary
Air flow (max) 380 m3/ Hour
Fan speeds 3 (H, M, L)
Exhaust hose length 5 ft.
Unit Dimensions 20.5" L x 19" H x 21.7" D
Unit Weight 79 lbs
Noise level (acoustic power) Min. 34– max. 43

* Uninsulated rooms such as sunrooms, garages, or attics should be less than 450 sq. ft.

ONE YEAR LIMITED WARRANTY & FIVE YEAR WARRANTY ON COMPRESSOR

This WHYNTER SNO portable air conditioner is warranted, to the original owner within the 48 continental states, for one year from the date of purchase against defects in material and workmanship under normal use and service. Should your SNO portable air conditioner prove defective within one year from the date of purchase, return the defective part or unit, freight prepaid (within two months of purchase; after two months to one year, customer will be responsible for freight cost to Whynter's service department), along with an explanation to Whynter's service department. Please ship the SNO portable air conditioner in its original packaging material to avoid damage in transit. Please retain original box and packaging material. Under this warranty, Whynter will repair or replace any parts found defective. This warranty is not transferable. After the expiration of the warranty, the cost of labor and parts will be the responsibility of the original owner of the unit.

THIS WARRANTY DOES NOT COVER:

  • Acts of God, such as fire, flood, hurricanes, earthquakes and tornadoes.
  • Damage, accidental or other wise, to the portable air conditioner while in the possession of a consumer not caused by a defect in material or workmanship;
  • Damage caused by consumer misuse, tampering, or failure to follow the care and special handling provisions in the instructions.
  • Damage to the finish of the housing, case, or other appearance parts caused by wear.

1) Filter.
2) Damage caused by repairs or alterations of the unit by anyone other than authorized by the manufacturer.
3) Freight and Insurance cost for the warranty service.

To obtain service or information, contact

Whynter Innovations Group via Email at service@whynter.com or call 866-WHYNTER.

Manual assistant