Festo

VACN-N-K1-1-EX4-M - Ukategoriseret Festo - Gratis brugsanvisning og manual

Find enhedens vejledning gratis VACN-N-K1-1-EX4-M Festo i PDF-format.

📄 1 sider Dansk DA Download 💬 AI-spørgsmål
Notice Festo VACN-N-K1-1-EX4-M - page 1
Pick your language and provide your email: we'll send you a specifically translated version.

Brugerspørgsmål om VACN-N-K1-1-EX4-M Festo

0 spørgsmål om dette apparat. Besvar dem du kender, eller stil dit eget.

Stil et nyt spørgsmål om dette apparat

E-mailen forbliver privat: den bruges kun til at underrette dig, hvis nogen svarer på dit spørgsmål.

Ingen spørgsmål endnu. Vær den første til at stille et.

Download vejledningen til din Ukategoriseret i PDF-format gratis! Find din vejledning VACN-N-K1-1-EX4-M - Festo og tag din elektroniske enhed tilbage i hånden. På denne side er alle dokumenter nødvendige for brugen af din enhed offentliggjort. VACN-N-K1-1-EX4-M af mærket Festo.

BRUGSANVISNING VACN-N-K1-1-EX4-M Festo

Festo VACN-N-K1-1-EX4-M - 1

natural_image Technical line drawing of a mechanical component with a curved shaft and housing (no text or symbols)

FESTO

Festo SE & Co. KG

Ruiter Straße 82

73734 Esslingen

Germany

+49 711 347-0

www.festo.com

Operating instruction

8186786

2022-12c

[8186788]

Festo VACN-N-K1-1-EX4-M - FESTO - 1
8186786

Translation of the original instructions

© 2023 all rights reserved to Festo SE & Co. KG

1 Identification EX

Marking Certificate
Ex mb IIC T6Ex mb tb IIIC T80°CIECEx PTB 15.0016 X
CEII 2G Ex mb IIC T6 GbII 2D Ex mb tb IIIC T80°C DbPTB 14 ATEX 2027 X
UKCAII 2G Ex mb IIC T6 GbII 2D Ex mb tb IIIC T80°C DbPTB 14 ATEX 2027 X
SegurangaINMETROEx mb IIC T6 GbEx mb tb IIIC T80°C DbDNV 15.0016X
Ex mb IIC T6 GbEx mb IIIC T80°C DbGYJ21.1327X

Tab. 1: Identification EX

2 Applicable documents

NOTICE

Technical data for the product can have different values in other documents. For operation in an explosive atmosphere, the technical data in this document always have priority.

Festo VACN-N-K1-1-EX4-M - NOTICE - 1

All available documents for the product → www.festo.com/sp.

3 Certified solenoid coils

Voltage Cable length Type T. no.
24 V DC 3 m VACN-N-K1-1-EX4-M 8029143
24 V DC 10 m VACN-N-K1-1-10-EX4-M 8141606
110 V AC 3 m VACN-N-K1-16B-EX4-M 8029142
230 V AC 3 m VACN-N-K1-3A-EX4-M 8029141

Tab. 2: Certified solenoid coils

4 Safety

4.1 General safety instructions

  • The device can be used under the stated operating conditions in zones 1 and 2, explosive gas atmospheres, and in zones 21 and 22, explosive dust atmospheres.
  • The device may only be used in the delivered configuration in a potentially explosive atmosphere.
  • Use the device in its original status without any unauthorised modifications.
  • All work must be carried out outside of potentially explosive areas.

4.2 Intended use

The solenoid coil is an actuator for Festo valves.

4.3 Identification X: special conditions

  • Install a fuse or a motor protection switch appropriate for the rated current upstream of the solenoid coil as short-circuit protection.
  • Short circuit protection for max. 3 times the rated current in accordance with IEC 60127-1.
  • The fuse with the lowest current value in accordance with IEC 60127-1 is sufficient for very low rated currents of the solenoid coil.
  • Select the fuse rated voltage equal to or greater than the nominal voltage of the solenoid coil.
  • Motor protection switch with short circuit triggering and thermal quick triggering, adjustment to rated current.
  • Install the fuse in the supply unit or wire it separately upstream.
  • The interruption rating of the fuse unit must be greater than or equal to the maximum expected short-circuit current at the installation location, normally 1500 A.
  • Max. permissible ripple with solenoid coils in direct current: 20%.

5 Function

When switching on the voltage, the solenoid is energised, and the valve is actuated.

6 Commissioning

Festo VACN-N-K1-1-EX4-M - Commissioning - 1

WARNING

The discharge of electrostatically charged parts can lead to ignitable sparks.

  • Prevent electrostatic charging by taking appropriate installation and cleaning measures.
  • Include the device in the system equipotential bonding.

NOTICE

Installation and commissioning should only be carried out in accordance with operating instructions and by qualified personnel.

  • Prevent short circuit or interruption resulting from bending the connecting cable too tightly.
  • Observe the product labelling.
  • Do not commission the solenoid coil until after mounting.

7 Maintenance and care

Festo VACN-N-K1-1-EX4-M - Maintenance and care - 1

WARNING

The discharge of electrostatically charged parts can lead to ignitable sparks. If used in group IIC:

- Only clean the device with a damp cloth.

– Repairs to the solenoid coil are not permitted.
- The device is maintenance-free.

8 Technical data

Technical data

Ambient temperature Ta
Individual mounting [°C]-20 ≤ Ta ≤ +50
Block mounting[°C]-20 ≤ Ta ≤ +40
Nominal voltage Un
VACN-N-K1-1-EX4-M[V DC]24
VACN-N-K1-1-10-EX4-M[V DC]
VACN-N-K1-16B-EX4-M[V AC]110 (50 ... 60 Hz)120 (60 Hz)
VACN-N-K1-3A-EX4-M[V AC]230 (50 ... 60 Hz)
Rated current In
VACN-N-K1-1-EX4-M[mA]109
VACN-N-K1-1-10-EX4-M[mA]
VACN-N-K1-16B-EX4-M[mA]22
VACN-N-K1-3A-EX4-M[mA]9
Duty cycle[%] 100 (continuous operation)
Degree of protectionIP65
Relative humidity[%] 95 (non-condensing)
AssemblyIndividual mounting/block mounting
Block mounting, minimum distance
VACN-N-K1-1-EX4-M[mm]2
VACN-N-K1-1-10-EX4-M[mm]
VACN-N-K1-16B-EX4-M[mm]1
VACN-N-K1-3A-EX4-M[mm]1
Mounting positionany

Tab. 3: Technical data