BRUKSANVISNING EWF2CBPA ELECTROLUX
SYSTEM SPECIFICATION AND PERFORMANCE DATA SHEET
pure advantage™ NGFC-2000 Ice Maker Filter System
APPLICATION GUIDELINES / CONDITIONS OF USE
| Water Supply | Municipal or well applications |
| Water Temp. | Max. 100°F (38°C), Min. 33°F (0.6°C) - For cold water use only |
| Water Pressure | 100 psi (690 kPa) Max. 30 psi (207 kPa) Min., as measured at the valve inlet |
| The filter cartridge should be replaced at least every six months for the product to perform as advertised. Please refer to the Use and Care Manual for general operation and maintenance requirements. Your refrigerator will have an electronic light on the freezer door dispenser that lights up yellow when the filter is almost ready for replacement and lights up red when the filter must be replaced. The indicator is pressed for approximately 3-10 seconds to reset after replacing the filter cartridge. Please refer to the Use & Care Manual for complete instructions. The water filter status light on this model is not tested or certified by NSF.Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.While testing was performed under standard laboratory conditions, actual performance may vary. High sediment areas may require more frequent filter cartridge replacement.pure advantageTM NGFC-2000 Water Filter System will absorb bad tastes and odors in both ice cubes and drinking water. | |
SYSTEM SPECIFICATIONS
| Flow Rate | Ice Maker - 3.4 to 4.3 oz (99 - 125 cc) per 6.3 seconds at 60 psi (as measured at valve inlet)Dispenser - 60 oz per minute (0.5 gpm or 1.9 liters per minute) at 60 psi (as measured at valve inlet) |
| Capacity | 240 gallons (908.5 liters) |
| System Construction | Filter Housing Assembly - Polypropylene PlasticWater Storage Tank - Polyethylene PlasticTubing - Polyethylene PlasticFilter Media - Extruded Carbon Block |
REPLACEMENT CARTRIDGE INFORMATION
| Replacement cartridges are available through your local Electrolux dealer by calling the Consumer Care Center at 1-877-435-3287.Please reference Installation Instructions in the Use & Care Manual for replacing the cartridge and warranty information. Estimated cost for the replacement filter cartridge kit:Less than $50.00 |
PERFORMANCE DATA
| MODEL: pure advantageTMNGFC-2000 | Use the replacement cartridge listed below. |
| NSF. | The pure advantageTM NGFC-2000 system with the FC-300 cartridge has been tested according to NSF/ANSI 42/53 for reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water entering the system, as specified in NSF/ANSI 42/53. |
| General testwater parameters; pH = 7.5 +/- 0.5 Temp. 20°C +/-3°C (68°F +/-5°F) Pressure = 60 psi (414 kPa) @ 0.5 gpm (1.9 lpm) | |
| Substance Reduction | NSF Standard | NSF Reduction Requirements | Average Influent | Influent Challenge Concentration | Maximum Permissible Product Water Concentration | Maximum Effluent | Average Effluent | Average Percent Reduction | Minimum Percent Reduction |
| Chlorine taste and odor 42 >/= 50% | 1.9 mg/L 2.0 +/- 10% n/a 0.05 mg/L 0.05 mg/L | 97.40% 97.40% | |||||||
| Cyst 53 99.95% | 127500 cnt/mL | Min. 50,000 | n/a | 1 cnt/L | 1 cnt/L | 99.99% | 99.99% | ||
| 2,4-D | 53 | n/a | 0.222 mg/L | 0.210 +/- 10% | 0.07 mg/L | 0.043 mg/L | 0.012 mg/L | 94.50% | 80.60% |
| Alachlor | 53 | n/a | 0.385 mg/L | 0.04 +/- 10% | 0.002 mg/L | 0.002 mg/L | 0.0012 mg/L | 97.00% 95.00% | |
| Atrazine | 53 | n/a | 0.0083 mg/L | 0.009 +/- 10% | 0.003 mg/L | 0.0005 mg/L | 0.0005 mg/L | 94.00% 94.00% | |
| Lead 8.5 pH | 53 | n/a | 0.147 mg/L | 0.15 +/- 10% | 0.01 mg/L | 0.002 mg/L | 0.0012 mg/L | 99.10% 98.50% | |
| Lead 6.5 pH | 53 | n/a | 0.142 mg/L | 0.15 +/- 10% | 0.01 mg/L | 0.001 mg/L | 0.001 mg/L | 99.30% | 99.30% |
| Mercury 8.5 pH | 53 | n/a | 0.006 mg/L | 0.006 +/- 10% | 0.002 mg/L | 0.0019 mg/L | 0.0015 mg/L | 82.40% | 68.20% |
| Mercury 6.5 pH | 53 | n/a | 0.006 mg/L | 0.006 +/- 10% | 0.002 mg/L | 0.0002 mg/L | 0.0002 mg/L | 96.50% | 96.50% |
| Lindane | 53 | n/a | 0.0019 mg/L | 0.002 +/- 10% | 0.0002 mg/L | 0.00002 mg/L | 0.00002 mg/L | 98.90% | 98.90% |
| Toxaphene | 53 | n/a | 0.0155 mg/L | 0.015 +/- 10% | 0.003 mg/L | 0.001 mg/L | 0.001 mg/L | 93.50% | 93.40% |
| Particulate class I | 42 >= 85% | 8,966,666 part./mL | Min. 10,000 part./mL | >/= 85% | 14000 part./mL | 10050 mL | 99.90% | 99.80% | |
| Turbidity | 53 | n/a | 11 NTU | 11 +/- NTU | 0.5 NTU | 0.4 NTU | 0.1625 NTU | 98.50% 96.40% | |
| Endrin | 53 | 66.60% | 0.006 mg/L | 0.006 +/- 10% | 0.002 mg/L | 0.0002 mg/L | 0.0002 mg/L | 96.80% | 96.80% |
| Ethylbenzene | 53 | 66.60% | 2.08 mg/L | 2.1 +/- 10% | 0.7 mg/L | 0.0005 mg/L | 0.0005 mg/L | 99.90% | 99.90% |
| O-Dichloro benzene | 53 | 66.60% | 1.8 mg/L | 1.8 +/- 10% | 0.6 mg/L | 0.0005 mg/L | 0.0005 mg/L | 99.90% | 99.90% |
| P-Dichloro benzene | 53 | 66.60% | 0.22 mg/L | 0.225 +/- 10% | 0.075 mg/L | 0.0005 mg/L | 0.0005 mg/L | 99.80% | 99.80% |
| Asbestos | 53 | >99% | 72 MLF | 10-100 MLF | NA | 0.17 MLF | 0.17 MLF | >99.00% | >99% |
| Benzene | 53 66.60% 0.016 mg/L | 0.015 +/- 10% | 0.005 mg/L | 0.0005 mg/L | 0.0005 mg/L | 96.80% | 96.80% | ||
| Carbofuran | 53 | 50.00% | 0.079 mg/L | 0.08 +/- 10% | 0.04 mg/L | 0.0006 mg/L | 0.0018 mg/L | 97.80% 97.80% | |
MLF = Million fibers per liter
State of California
Department of Public Health
Water Treatment Device
Certificate Number
01 - 1474
Date Issued: April 25, 2011
| Trademark/Model Designation | Replacement Elements |
| Frigidaire PureSource 2 NGFC-2000 | FC-100 |
| FC-300 | |
| Electrolux Pure Advantage NGFC 2000 | FC-100 |
| FC-300 | |
| Pure Advantage NGFC 2000 (Icemaker only) | FC-300 |
| Manufacturer: Electrolux Home Products | |
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section 116830 of the Health and Safety Code for the following health related contaminants:
Microbiological Contaminants and Turbidity Inorganic/Radiological Contaminants
| Cysts (protozoan) | Lead |
| Turbidity | Mercury |
| Organic Contaminants | |
| Alachlor | |
| Atrazine | |
| Lindane | |
| 2,4-D | |
| Toxaphene | |