USER MANUAL MUH360 N'oveen
natural_image
Two white N'OVEEN water purifiers with control knobs, no visible text or symbols on the devices themselves.INSTRUKCJA OBSŁUGI
USE INSTRUCTIONS
POLSKI s. 2
ENGLISH p. 7
natural_image
Close-up of white plastic components with arrows indicating direction, no visible text or symbols
natural_image
Close-up of white plastic components with arrows indicating direction, no visible text or symbolsnatural_image
Four-panel image showing a white plastic comb with ribbed structure before and after modification, labeled zdj. 3 to zdj. 6 (no text or symbols on the objects themselves)The humidifier helps to eliminate the discomfort of dry air. Ultrasonic humidifier uses ultrasound to break down water molecules and generate mist. Read all safety instructions before use and keep this manual for later reference.
- Do not overfill the tank, unbalanced movement may cause excess water to run into the main body and damage the base unit.
- Do not touch the water in any part of the machine when the humidifier is working.
- Do not direct the sprayer nozzle towards children, furniture, walls, etc. Point it towards an empty space instead.
- Make sure the Ultrasonic Humidifier is positioned far away from other home appliances.
- Place the unit on an even, stable surface when in operation.
- When cleaning or moving the unit, turn it off, unplug it and remove the water tank.
• Take special care not to let water spill into the base.
- Do not place the humidifier in sun-lit places for long periods of time.
- Do not attempt to repair or replace parts yourself. Contact the Service Centre.
- Please unplug and store the Humidifier in its original packaging if it is not to be used for a long period of time.
- Never leave the appliance unattended while in use.
• Always unplug the appliance before filling it with water.
- Do not add any additives to the water (salt, oils, perfumes, etc.), which have not been provided by the distributor.
- Do not put the Humidifier on tables or on parquet or wooden flooring.
NOTE -The maximum operating time of the Humidifier is 12 hours.
1. Specifications
Water tank: 3.5 L
Power: 24 W
Maximum rating: 360 ml / hr
2. Components description

text_image
Nozzle Nozzle connection seat Handle Water tank Water tank bottom Thimble silicone Tank cover sealing ring Tank cover Thimble Float gland Float Fan Sensor Mist adjustment Fan cover Power Supply Board Dry reed pipe Dry reed pipe slice Aromization plate Anion Filter cotton tray Main body3. General Introduction
The Ultrasonic Humidifier is made of recyclable plastic. It operates quietly, producing a cold, fine mist, the output of which can be regulated.
4. How Does it Work?
As per the vibrating theory of ultrasonic waves, the Ultrasonic humidifier uses the ultrasonic, high-frequency oscillator to break up water into tiny water particles with a diameter of about 1-5pm. The ventilation system then blows this water out into the dry air, where it evaporates to provide the required humidity. A mist will thus be released through the nozzle.
5. Directions
- Keep the unit under room temperature conditions for at least half an hour, before running the first operation.
- It is recommended to use the unit under temperature conditions of between 5 - 40 °C, and a relative humidity of less than 80 %RH.
- Remove the water tank from the main body, remove the tank cover found at the base of the water tank and fill the tank with tap water (not more than 40^ ), and securely tighten the tank cover to the water tank.
- Make sure that there are no debris in the main body that can damage the transducer..
- Connect the power plug and switch on the unit (NEVER SWITCH THE UNIT ON WHEN THERE IS NO WATER IN THE MAIN BODY), the main control lamp will then turn on.
- The unit is now ready for use.
- Turn the regulation knob to the desired setting
In the case of lack of water, the device will stop working but the power light will remain on!
6. Filling the tank with water
Remove the water tank from the main body, unscrew the tank cap located in the tank base (zdj.1) and fill the tank with tap water (at a temperature no higher than 40^ C) and securely screw the cap (zdj.2)

natural_image
Close-up of white plastic cups with arrows pointing to them, no visible text or symbols
natural_image
Close-up of white plastic components with arrows indicating direction, no visible text or symbols7. Dispensing oils
To use the aromatic oils you must do the following.
The dispenser is located on the back of the device (zdj. 3), pull it out (zdj. 4), then on the sponge in the middle (zdj. 5), put the right amount of oil (as desired). Then, close the dispenser to the position as in a photo (zdj.6). The device is ready for use.

natural_image
Four-panel image showing a white plastic comb with serrated edges, labeled zdj. 3 to zdj. 6, showing a step-by-step assembly of the comb and final product.8. Cleaning and Maintenance
8.1 Water Tank
Before cleaning, ensure that the unit is switched off. Clean after every use and do not keep water in the tank for longer than 2 days.
8.2 Transducer
To clean the (main body) transducer, add some de-scaling cleanser (about 0.5 g powder) onto the transducer and then add a small amount of water and wait for 2-5 minutes. Use a soft brush to clean. Do not use soap or other alkaline substances to clean the transducer.
9. Storage
We recommend that you store your Ultrasonic Humidifier in the original packaging. Make sure that all the parts are clean and dry before storage.
Troubleshooting
| Problem | Possible reasons | Solution |
| Power light off | No power supply | Connect to power supply, switch on |
| Power light on, with breeze and no mist | No water in the water tank | Fill water into the water tank. Note: transducer may have already been damaged |
| Abnormal smell from the mist | New units may emit a strange odor | Remove the water tank, open the tank cover and let it stay out in the open for 12 hours in a cool, dry area |
| Dirty water in the tank or water in the tank has been kept for too long | Clean the water tank and fill with clean water | |
| Power light on, with low intensity | Too much water in the main body | Pour some water out from the main body, close the tank cover securely |
| Low intensity mist | Too much scale in the main body | Clean the transducer |
| Dirty water in the tank or water in the tank has been kept for too long | Clean the water tank and fill with clean water | |
| Abnormal noise | Resonance caused by too little water in the water tank | Fill with clean water |
| Resonance caused by an unstable surface | Move the unit to a stable flat surface | |
| Mist coming out beyond the nozzle | There are apertures between the nozzle and the water tank | Dip the nozzle in water for a while and then attach it to the socket on the water tank |
Remember that before performing any activity consisting of opening, lifting or replacing, including dispensing oils, disconnect the device from the power supply !!!