BRUGSANVISNING Go Recovery Boots Reboots
SAFETY WARNING
Keep these operating Instructions in a safe place! Do not take apart or burn this device. Repairs to the control unit may only be carried out by persons authorised by Wellcocean GmbH, or the warranty may be invalidated. If this device becomes damaged, remove the power cord and turn off the device. Remove the power cord and turn off this device if it comes in contact with water or other liquids. Do not use this device in damp areas. Ensure that this device remains in good condition. Do not allow Rebeats Go and the built-in battery in particular to be shaken or throws.
Nothing should be placed on top of this device when it is in use. Be sure that the tubes do not become twisted or linked when the device is in use. Keep Robots Go away from heat sources (direct sunlight, radiators, etc.). Turn this device off when not in use.
Unplug the power card when the battery is fully charged or the device is not in use. Always unplug the device before cleaning. Never press-down on or pierce the fault-in battery. Keep Rabeots Ga away from children and anyone who has not been informed about their proper use. CE The manufacturer or Importer declares that this product meets the requirements of the applicable EC directives and confirms to the key requirements set therein.
This mark indicates that this device must be disposed of separately from normal household waste. Please take this device to an electronic waste facility when you wish to dispose of it.
WARRANTY
We provide a 24-month warranty for the control unit. If something goes wrong, it may be necessary to send in the unit for evaluation. When doing this, please make sure to package the unit accurate to avoid damage during transport. Defects resulting from improper packaging are not covered by the warranty. Warranty terms. Insofar as a legal obligation to provide warranty exists and with the exclusion of the right to cancellation or price reduction, a replacement will be provided at no cost or the manufacturer will have the opportunity to correct the defect. If the defect persists after multiple attempts to correct the problem, or the replacement unit is found to be defective from the manufacturer, the customer has the right to a cancellation or price reduction.
Warranty: Exclusion defects resulting from excessive force, improper use, violent impacts, or changes and repairs by third parties, such as damages from incorrectly-sized or shorted circuits, or damage resulting from normal wear and tear are excluded from warranty. Warranty Requirement; the warranty is only valid in conjunction with the original product receipt. Keep the product receipt in a safe place.
If you have any questions or problems with the use of this system, please contact us at +49 (2) 6644-919642 or service@wellcosan.de.
INCLUDES.


Boots(M/L/XL)


Operating Instructions

Tube Sett
TECHNISCHE DATEN
Power Output 14W Pump Capacity 40l/min Weight 1,6kg Pressure 30-240mmHg Dimensions 22×14×9cm
Charger 110-240V; 50-60Hz Charger Voltage DC C12.6V; 2A/3A Time Settings, up to 1.5 h
Number of Air 6 chambers Chambers Number of Settings 4 programs Charging Time ca. 130 min Battery Length ca. 180 min
LIABILITY DISCLAIMER
Do not use or ask your doctor before using Reboots Recovery Tech if you suffer from any of the following: acute heart failure, heart failure with oedema in the legs, swelling in the legs or feet diagnosed or suspected deep vein thrombosis, vein inflammation and arterial diseases, gangrene, dermatitis, atherosclerosis or venous circulatory disorders, open or infected wounds and injuries, pain in the legs, injuries to the skin, acute inflammations, malignant tumours, pulmonary oedema, high blood pressure, prolonged thrombophlebitis, diagnosed or suspected thrombosis, eyespelas, severe uncontrolled hypertension, acute soft tissue trauma of the extremities, peripheral neuropathy or lymphatic obstructions. The purpose of Reboots Recovery Tech is to help you improve your relaxation and well-being.
NOTICE: Reboots Recovery Tech is not a medical device and should not be used for self-treatment. If you are uncertain, please contact your doctor.
MANUFACTURER: Wellcosan GmbH, Hauptstraße 27, 36381 Schlüchtern, Germany Tel: +49(0)6664/919642 | Fax: +49(0)6664/919644 service@wellcosan.de | www.wellcosan.de © Wellcosan GmbH 2019
REBOOTS


1 INSERT MULTI-PLUG
There are two clips on the side of the Multi-Plug. The clips must be depressed in order to connect the Multi-Plug to the device. Once the clips are depressed, the Multi-Plug can be inserted. The cable must the removed in the same fashion after use.

2 PUT ON REBOOTS
It is generally best to pull the boots as high as you can. Only the tips of your toes (not the full toes!) should peak out of the ends. Keep your legs as horizontal as possible while using the Reboots, and make sure that the air tubes do not become kinked.

3 TURN ON THE CONTROL UNIT
On the right side of the unit, you will find the power switch. If the device does not turn on when the switch is flipped, the battery is likely drained. Use the included charging cable to recharge the battery.
USEBEFORE USE
4 SELECT LENGTH The default massage time is 30 min. You can use the buttons to shorten or longer the
■ You can continue the button to first hit or length them the programme one minute at a time. The maximum length is 99
minutes. The pump turns off automatically once the program
me has ended.
5 SELECT PRESSURE The default pressure is Level 8.
You can use the buttons to choose between 16 pressure levels.
pressure levels
6 SELECT PROGRAMME Programme A is selected as the default. The programme cannot be changed while it is
running. In order to change the programme, you must pause
the device.
7 DEACTIVATE CHAMBERS All compression chambers
I are active by default. If you would like to exclude certain chambers from the message you can do that in this step.
chambers from the massage, you can do that in this step.
8 START When you turn on the device, it will be in pause
mode (orange light). Push the start button to begin the recovery massage. Tip: the device can be used with a drained
battery as long as it is plugged in.

PROGRAMMES/GUIDE
Maximum regeneration for maximum performance: in order to achieve the best results from your recovery programme.
to achieve the best results from your Recovery programme, please note the following points:
USE
You can use Reboots both before and after exercising, either to help with relaxation and prevent exercise as to begin up.
to help with restakation and prevent soreness of to loosen up or muscles in advance. The focus of the massage depends on
the programme.
LENGTH AND FREQUENCY OF USE The minimum length of one after break
The optimum length for use after training is between 30 and 50 minutes. Before training, use between 10 and 20 minutes to loosen up your muscles. There is not set maximum length.
or frequency. In general, you may use your Reboots as long as
they feel good. After exercise, it is best to use Reboots on a
mid to high level of pressure. Before exercising, you can use Reboots at a mid-level pressure. As long as you feel comfort-
table during the massage programme, it is fine to use higher
pressure or longer programmes. We recommend moving slowly between pressure levels in order to find your optimal
setting. More is not always better: the recovery programme should never be unpleasant or painful.


Prolonged pressure in programme B prevents backflow. Programme B is intended primarily to aid in the removal of lactic acid. If you are a beginner, it is best to use programme A for a while first, before slowly introducing programme B. Programme D supplements programme C with a very effective pulse effect. The pressure in the last active chamber is raised three times and then reduced again. This allows time for metabolic waste to move through the tissue. The result is a particular thorough recovery programme